LA7SMU2 ;DALOI/JMC - Shipping Manifest Utility (Cont'd);5/5/97 14:44 ;;5.2;AUTOMATED LAB INSTRUMENTS;**46,64**;Sep 27, 1994 Q ; DTTO(LA7SCFG,LA7VNLT,LA7HLSC,LA764NCS,LA761NCS,LA7HLPRI,LA7CSC) ; Determine test to order ; Call with LA7SCFG = ien of Shipping Configuration file #62.9 ; LA7VNLT = NLT code or non-VA test code ; LA7HLSC = HL7 Specimen Code ; LA764NCS = HL7 Name of Test Coding System ; LA761NCS = HL7 Name of Specimen Coding System ; LA7HLPRI = HL7 Priority Code ; LA7CSC = collection sample code^name^coding system ; ; Returns LA7X = 0^0^0^0^^^ (if unsuccessful) ; LABORATORY TEST (ien file #60)^TOPOGRAPHY (ien file #61)^COLLECTION SAMPLE (ien file #62)^URGENCY (ien file #62.05)^NLT TEST CODE^NLT TEST NAME ; N LA760,LA7V64,LA7X,X,Y,Z ; ; Make sure variables initialized. S LA7X="0^0^0^0^^^" I LA7VNLT="" Q LA7X S LA7SCFG=+$G(LA7SCFG) I LA7HLPRI="" S LA7HLPRI="R" I LA7HLSC="" S LA7HLSC="XXX" ; ; If coding systems not defined then assume ; HL7 Table 0070 and VA NLT file I LA761NCS="0070" S LA761NCS="HL70070" I LA761NCS="" S LA761NCS="HL70070" I LA764NCS="" S LA764NCS="99VA64" I LA764NCS="L",$P(^LAHM(62.9,LA7SCFG,0),"^",15)=0 S LA764NCS="99VA64" ; ; Build index of tests if not previously done for this session. I '$D(^TMP("LA7TC",$J,LA7SCFG)) D BINDX ; ; Found test info with priority I LA7HLPRI]"" D . I $P(LA7CSC,"^")'="" D Q:LA7X . . S X=$G(^TMP("LA7TC",$J,LA7SCFG,LA7VNLT,LA7HLSC,LA7HLPRI,$P(LA7CSC,"^"))) . . I X S LA7X=X . S X=$G(^TMP("LA7TC",$J,LA7SCFG,LA7VNLT,LA7HLSC,LA7HLPRI)) . I X S LA7X=X Q . S X=$G(^TMP("LA7TC",$J,LA7SCFG,LA7VNLT,"XXX",LA7HLPRI)) . I X,"MISPCYEM"[$P(^LAB(60,+X,0),"^",4) S LA7X=X ; ; Found test info with no priority specified I 'LA7X D . I $P(LA7CSC,"^")'="" D Q:LA7X . . S X=$G(^TMP("LA7TC",$J,LA7SCFG,LA7VNLT,LA7HLSC,0,$P(LA7CSC,"^"))) . . I X S LA7X=X . S X=$G(^TMP("LA7TC",$J,LA7SCFG,LA7VNLT,LA7HLSC)) . I X S LA7X=X Q . S X=$G(^TMP("LA7TC",$J,LA7SCFG,LA7VNLT,"XXX")) . I X,"MISPCYEM"[$P(^LAB(60,+X,0),"^",4) S LA7X=X ; ; Otherwise get values from files #60 LABORATORY TEST and #61, TOPOGRAPHY ; Lookup test using NLT code and get first lab test in "AC" for this ; NLT code that's type (I)nput or (B)oth. I 'LA7X,LA764NCS="99VA64" D . S LA7V64=$O(^LAM("E",LA7VNLT,0)),Y=0 Q:'LA7V64 . F S Y=$O(^LAB(60,"AC",LA7V64,Y)) Q:'Y Q:"BI"[$P(^LAB(60,Y,0),"^",3) . I Y S $P(LA7X,"^")=Y ; ; Get default topography and collection sample for HL7 specimen type. ; Check file #60 collection samples first, then check first entry in file #61 for match ; If non-table 0070 then look for "XXX" in table 0070 I $P(LA7X,"^"),'$P(LA7X,"^",2),LA761NCS="HL70070" D . S (X,Y)=0,LA760=$P(LA7X,"^") . F S X=$O(^LAB(60,LA760,3,"B",X)) Q:'X D Q:Y . . S Z=$P(^LAB(62,X,0),"^",2) . . I Z,$D(^LAB(61,"HL7",LA7HLSC,Z)) S Y=Z_"^"_X . I Y S $P(LA7X,"^",2,3)=Y I '$P(LA7X,"^",2),LA761NCS="HL70070" D . S X=$O(^LAB(61,"HL7",LA7HLSC,0)) Q:'X . S $P(LA7X,"^",2)=X . I '$P(LA7X,"^",3) S $P(LA7X,"^",3)=$P(^LAB(61,X,0),"^",6) I $P(LA7X,"^"),'$P(LA7X,"^",2),LA761NCS'="HL70070","MISPCYEM"[$P(^LAB(60,$P(LA7X,"^"),0),"^",4) D . S X=$O(^LAB(61,"HL7","XXX",0)) . I X S $P(LA7X,"^",2)=X ; ; No urgency mapping, get last using this HL7 code or site's default urgency from #69.9 ; Find highest non-workload urgency using this priority code else use site's default I '$P(LA7X,"^",4) D . S X=$O(^LAB(62.05,"HL7",LA7HLPRI,50),-1) . I X S $P(LA7X,"^",4)=X . E S $P(LA7X,"^",4)=+$P($G(^LAB(69.9,1,3)),"^",2) ; ; Check file #60 forced and highest urgency. I $P(LA7X,"^"),$P(LA7X,"^",4) D . S X=$G(^LAB(60,$P(LA7X,"^"),0)) . I $P(X,"^",18) S $P(LA7X,"^",4)=$P(X,"^",18) . I $P(X,"^",16),$P(LA7X,"^",4)<$P(X,"^",16) S $P(LA7X,"^",4)=$P(X,"^",16) ; Q LA7X ; ; BINDX ; Build index of tests for a shipping configuration. ; Called from above. ; I '$D(^LAHM(62.9,LA7SCFG,0)) Q N LA760,LA761,LA762,LA76205,LA764,LA7HL,LA7NLT,LA7NLTN,LA7TC,LA7X S LA7X=0 F S LA7X=$O(^LAHM(62.9,LA7SCFG,60,LA7X)) Q:'LA7X D BLD Q ; ; BLD ; Build TMP global for a test ; Called from above ; S LA7X(0)=$G(^LAHM(62.9,LA7SCFG,60,LA7X,0)) S LA7X(5)=$G(^LAHM(62.9,LA7SCFG,60,LA7X,5)) ; ; Laboratory test/collection sample. S LA760=$P(LA7X(0),"^"),LA762=$P(LA7X(0),"^",9) ; Incomplete entry. I 'LA760!('LA762) Q ; ; Test urgency/HL7 priority code. S LA76205=$P(LA7X(0),"^",4),LA76205("HL")="" I LA76205 S LA76205("HL")=$$GET1^DIQ(62.05,LA76205_",","LEDI HL7:HL7 ABBR") ; ; Topography S LA761=$$GET1^DIQ(62,LA762_",",2,"I") I 'LA761,"BBCH"[$P(^LAB(60,LA760,0),"^",4) Q ; Incomplete entry. ; Handle MI with no topography associated with collection sample. I 'LA761,$P(^LAB(60,LA760,0),"^",4)="MI" S LA761=+$P(LA7X(0),"^",3) ; ; Use HL7 specimen code if using table 0070 else use mapping in 62.9 S LA7HL="" I LA761NCS="HL70070" S LA7HL=$$GET1^DIQ(61,LA761_",","LEDI HL7:HL7 ABBR") I LA7HL="" S LA7HL=$P(LA7X(5),"^",3) ; ; File #64 ien/NLT code/NLT code test name. ; Use NLT code if using VA coding else use non-VA test order code. S LA764=+$$GET1^DIQ(60,LA760_",",64,"I") S LA7NLT=$$GET1^DIQ(64,LA764_",",1) S LA7NLTN=$$GET1^DIQ(64,LA764_",",.01) I LA764NCS="99VA64" S LA7TC=LA7NLT E S LA7TC=$P(LA7X(5),"^") ; ; Set TMP global with information I LA7HL'="",LA7TC'="" D . I "MISPCYEM"[$P(^LAB(60,LA760,0),"^",4),$P(LA7X(5),"^",7)'="" D . . S ^TMP("LA7TC",$J,LA7SCFG,LA7TC,LA7HL,0,$P(LA7X(5),"^",7))=LA760_"^"_LA761_"^"_LA762_"^^"_LA7NLT_"^"_LA7NLTN . E S ^TMP("LA7TC",$J,LA7SCFG,LA7TC,LA7HL)=LA760_"^"_LA761_"^"_LA762_"^^"_LA7NLT_"^"_LA7NLTN . I LA76205("HL")'="" D . . I "MISPCYEM"[$P(^LAB(60,LA760,0),"^",4),$P(LA7X(5),"^",7)'="" D . . . S ^TMP("LA7TC",$J,LA7SCFG,LA7TC,LA7HL,LA76205("HL"),$P(LA7X(5),"^",7))=LA760_"^"_LA761_"^"_LA762_"^"_LA76205_"^"_LA7NLT_"^"_LA7NLTN . . E S ^TMP("LA7TC",$J,LA7SCFG,LA7TC,LA7HL,LA76205("HL"))=LA760_"^"_LA761_"^"_LA762_"^"_LA76205_"^"_LA7NLT_"^"_LA7NLTN ; ; Set TMP global when collection sample does not have a topography. ; Used for "MISPCYEM" subscripts which can have collection sample with no tpopgraphy. I LA7TC'="",'LA761,"MISPCYEM"[$P(^LAB(60,LA760,0),"^",4) D . S ^TMP("LA7TC",$J,LA7SCFG,LA7TC,"XXX")=LA760_"^"_LA761_"^"_LA762_"^^"_LA7NLT_"^"_LA7NLTN . I LA76205("HL")'="" S ^TMP("LA7TC",$J,LA7SCFG,LA7TC,"XXX",LA76205("HL"))=LA760_"^"_LA761_"^"_LA762_"^"_LA76205_"^"_LA7NLT_"^"_LA7NLTN ; Q