ENEQMED2 ;WISC/SAB-Multiple Equipment Edit, continued ;9/24/97 ;;7.0;ENGINEERING;**35,39,45**;Aug 17, 1993 UPD ; update equipment S DIR(0)="Y",DIR("A")="OK to update the "_ENC("SEL")_" selected items" D ^DIR K DIR G:$D(DIRUT)!'Y EXIT ; S ENDA=0 F S ENDA=$O(^TMP($J,"ENSEL",ENDA)) Q:'ENDA D . ; lock individual item when not locking as batch; skip if unable . I 'ENLOCK("BATCH") L +^ENG(6914,ENDA):1 I '$T D Q . . S ^TMP($J,"ENLCK",ENDA)="" ; put skipped equipment on list . S ENFLD=0 F S ENFLD=$O(^TMP($J,"ENFLD",ENFLD)) Q:'ENFLD D . . S ENFLDN=$$GET1^DID(6914,ENFLD,"","LABEL") . . S ENVALI=$P(^TMP($J,"ENFLD",ENFLD),U) . . I ENFLD=30 D Q ; pm data . . . ; delete old PM data (if any) . . . S ENDAPM=0 F S ENDAPM=$O(^ENG(6914,ENDA,4,ENDAPM)) Q:'ENDAPM D . . . . K DA S DA(1)=ENDA,DA=ENDAPM,DIK="^ENG(6914,"_ENDA_",4," . . . . D ^DIK K DIK . . . ; move new PM data via %RCR . . . S ENDAT=$G(^TMP($J,"ENFLD",30)) Q:'ENDAT . . . S %X="^ENG(6914,"_ENDAT_",4,",%Y="^ENG(6914,"_ENDA_",4," . . . D %XY^%RCR . . . ; reindex PM data . . . S ENDAPM=0 F S ENDAPM=$O(^ENG(6914,ENDA,ENDAPM)) Q:'ENDAPM D . . . . K DA S DA(1)=ENDA,DA=ENDAPM,DIK="^ENG(6914,"_ENDA_",4," . . . . D IX1^DIK K DIK . . I ENFLD=40 D Q ; comments . . . D WP^DIE(6914,ENDA_",",40,"A","^TMP($J,""ENCOM"")","ENERR()") . . I ENFLD=70 D Q ; spex . . . D WP^DIE(6914,ENDA_",",70,"A","^TMP($J,""ENSPEX"")","ENERR()") . . I ENVALI']"" S ENVALI=$P($G(^TMP($J,"ENFLD",ENFLD,ENDA)),U) . . I ENVALI']"" Q . . I ENFLD=2,ENVALI=ENDA Q ; can't be it's own parent . . S DA=ENDA,DIE=6914,DR=ENFLD_$S(ENVALI]"":"////^S X=ENVALI",1:"") . . D ^DIE K DIE . ; did both life expectency and CSN get updated? . I $D(^TMP($J,"ENFLD",15)),$D(^TMP($J,"ENFLD",18)) D . . ; must redo life expectancy because CSN trigger overwrote . . S ENVALI=$P(^TMP($J,"ENFLD",15),U) . . I ENVALI']"" Q . . S DA=ENDA,DIE=6914,DR="15////^S X=ENVALI" . . D ^DIE K DIE . ; unlock individual item when not locking as batch . I 'ENLOCK("BATCH") L -^ENG(6914,ENDA) . W "." I $D(^TMP($J,"ENLCK")) D . W $C(7),!!,"Warning: Some of the selected equipment could not be" . W !,"updated because it was being being edited by another process." . W !,"These equipment items will need to be edited to make the" . W !,"desired changes. Print the report for more information.",! . S DIR("B")="YES" S DIR(0)="Y",DIR("A")="Would you like a list of modified equipment" D ^DIR K DIR G:$D(DIRUT)!'Y EXIT D EN^ENEQMED3 EXIT ; ; delete dummy record created for PM data (if any) I $G(ENDAT)>90000000000 D . ; delete responsible shops to clean up AB x-ref . S ENDAPM=0 F S ENDAPM=$O(^ENG(6914,ENDAT,4,ENDAPM)) Q:'ENDAPM D . . K DA S DA(1)=ENDAT,DA=ENDAPM,DIK="^ENG(6914,"_ENDAT_",4," . . D ^DIK K DIK . ; delete renamining data (wasn't created via FileMan so don't use now) . K ^ENG(6914,ENDAT) . L -^ENG(6914,ENDAT) ; unlock selected equipment (if any) I $G(ENLOCK("BATCH")) D . S ENDA=0 . F S ENDA=$O(^TMP($J,"ENSEL",ENDA)) Q:'ENDA L -^ENG(6914,ENDA) ; clean up variables K ^TMP($J) K %X,%Y,DA,DIC,DIQ,DIWESUB,DR,DUOUT,DTOUT,DIRUT,DIROUT,X,Y K ENA,ENASK,ENC,ENCAT,ENCATI,ENDA,ENDAPM,ENDAT,ENDX,ENEDNX K ENFA,ENFLD,ENFLDN,ENGOT,ENI,ENL,ENLOCK,ENMAN,ENMANI K ENMOD,ENNX,ENPO,ENVALE,ENVALI,ENX,ENXP Q ;ENEQMED2