ENSA3 ;(WASH ISC)/DH-Process MedTester Data ;4.22.99 ;;7.0;ENGINEERING;**14,54**;Aug 17, 1993 NOLBL ;No barcode label scanned S EN="" I ENMOD]"",$D(^ENG(6914,"E",ENMOD)) S I=0 F J=0:0 S I=$O(^ENG(6914,"E",ENMOD,I)) Q:I'=+I I $D(^ENG(6914,I,1)),$P(^(1),U,3)=ENSN D MATCH,POST^ENSA4 Q ;If match found EN will be killed I $D(EN) D . S ENMSG="ITEM NOT FOUND IN DATABASE. MedTester REC # "_ENREC . S ENMSG(0,1)="Model: "_$S(ENMOD]"":ENMOD,1:"Unknown") . S ENMSG(0,2)="Serial Number: "_$S(ENSN]"":ENSN,1:"Unknown") . D XCPTN^ENSA2 Q MATCH ;Equipment unlabelled but present in 6914 S ENEQ=I D UPDATE1^ENSA2 K EN Q ; HOLD U IO(0) W !,"Press RETURN to continue..." R X:DTIME Q ERR ;Error message (Forced exit) W !!,*7,"FATAL ERROR OR USER ABORT.",*7 W !!,"Unrecoverable error has occurred. You will need to start the MedTester",!,"upload again from the beginning." S ENY=0 D HOLD EXIT I $E(IOST,1,2)="C-",$D(ENY),ENY>0 D HOLD K:$D(ENTID) ^ENG("TMP",ENTID) EXIT1 K EN,ENSA1,ENSA2,ENEQ,ENLBL,ENMSG,ENY,ENBRANCH,ENCAT,ENFAIL,ENFLG,ENMAN,ENMOD,ENMEN,ENDATE,ENSTA,ENSTAL K ENLOC,ENOLDLOC,ENEMP,ENPM,ENPMDT,ENPMWO,ENSHABR,ENSTDT,ENSHOP,ENSHKEY,ENDTCP,ENH,ENINV,ENPG,ENWOX,ENW,ENCOST K ENPAPER,ENPMN,ENREC,ENSN,ENTEC,ENWP,ENX,ENY,ENTID,EN1,EN2,ENAUTO,ENCTCLOS,ENCTEOFF,ENCTEON,ENCTOPEN,ENCTTYPE,ENTIME,ENTEST K %,I,I1,J,K,DA,DIC,DIE,DR,ENDEL,X,Y,X1,X2,%DT,DNX W @IOF I $E(IOST,1,2)="P-",'$D(ZTQUEUED) D ^%ZISC K ^TMP($J) Q ;ENSA3