source: FOIAVistA/tag/r/IFCAP-PRC-PRX--PRCA--PRCN/PRCPCDIK.m@ 636

Last change on this file since 636 was 628, checked in by George Lilly, 14 years ago

initial load of FOIAVistA 6/30/08 version

File size: 4.0 KB
Line 
1PRCPCDIK ;WISC/RFJ-disassemble instrument kit ;01 Sep 93
2 ;;5.1;IFCAP;;Oct 20, 2000
3 ;Per VHA Directive 10-93-142, this routine should not be modified.
4 D ^PRCPUSEL Q:'$G(PRCP("I"))
5 I PRCP("DPTYPE")'="P" W !,"THIS OPTION SHOULD ONLY BE USED BY A PRIMARY INVENTORY POINT." Q
6 N %,IKITEM,DATA,ITEMDA,ITEMDATA,NOTINVPT,ORDERNO,PRCPCDIK,PRCPID,QUANTITY,TOTVAL,X,Y
7 I $$CHECK^PRCPCUT1(PRCP("I")) Q
8 S IOP="HOME" D ^%ZIS K IOP
9 K X S X(1)="The Disassemble Instrument Kit option will break down the instrument kit and return the individual disposable items back to stock."
10 S X(2)="When a instrument kit is disassembled, the quantity on-hand for the instrument kit will be decremented and the quantity on-hand for the disposable items will be incremented. The quantity on-hand for reusable items will not change."
11 S X(3)="The disposable item quantity to return to stock equals the quantity used for the item during assembly of the instrument kit."
12 S X(4)="This quantity may be different from the instrument kit definition quantity since the instrument kit definition may have been altered after the instrument kit was assembled."
13 D DISPLAY^PRCPUX2(40,79,.X)
14DISASMBL ; disassemble instrument kit
15 K NOTINVPT,ORDERNO,PRCPFLAG
16 W ! S ITEMDA=$$SELECT^PRCPCED0("K",0,PRCP("I")) I ITEMDA<1 Q
17 S ITEMDATA=$G(^PRCP(445,PRCP("I"),1,ITEMDA,0))
18 I ITEMDATA="" W !!,"Instrument Kit is not stored as an item in the inventory point." G DISASMBL
19 I '$P(ITEMDATA,"^",7) W !!,"Instrument Kit has not been assembled (quantity on-hand is zero)." G DISASMBL
20 W ! S QUANTITY=$$QUANTITY^PRCPCUT1($P(ITEMDATA,"^",7),"D") I 'QUANTITY G DISASMBL
21 L +^PRCP(445.8,ITEMDA):5 I '$T D SHOWWHO^PRCPULOC(445.8,ITEMDA,0),EXIT G DISASMBL
22 D ADD^PRCPULOC(445.8,ITEMDA,0,"Disassemble Instrument Kit")
23 ;
24 ; show items in ik
25 D PRINT^PRCPCDIR(ITEMDA,QUANTITY)
26 ; some items not in inventory point message
27 I $G(NOTINVPT) D D EXIT G DISASMBL
28 . K X S X(1)="WARNING -- Before disassembling a instrument kit, all items used to build the instrument kit must be contained in the inventory point."
29 . D DISPLAY^PRCPUX2(20,60,.X)
30 . D R^PRCPUREP
31 ;
32 ; no items to build list with
33 I '$O(^TMP($J,"PRCPCDIR",0)) D D EXIT G DISASMBL
34 . K X S X(1)="There are no items or defined quantities for disassembling the instrument kit."
35 . D DISPLAY^PRCPUX2(20,60,.X)
36 . K X S X(1)="Disassembling Instrument Kit" D DISPLAY^PRCPUX2(1,79,.X)
37 . ; decrement instrument kit item
38 . S ORDERNO=$$ORDERNO^PRCPUTRX(PRCP("I"))
39 . S ITEMDATA=^PRCP(445,PRCP("I"),1,ITEMDA,0),TOTVAL=$J(QUANTITY*$P(ITEMDATA,"^",22),0,2)
40 . K PRCPCDIK S PRCPCDIK("QTY")=-QUANTITY,PRCPCDIK("INVVAL")=-TOTVAL,PRCPCDIK("REASON")="0:Disassembled Instrument Kit"
41 . D ITEM^PRCPUUIP(PRCP("I"),ITEMDA,"S",ORDERNO,.PRCPCDIK)
42 ;
43 ; user entered '^' during list display
44 I $G(PRCPFLAG) D D EXIT G DISASMBL
45 . K X S X(1)="You must display the entire list of items for the instrument kit before you can disassemble it."
46 . D DISPLAY^PRCPUX2(20,60,.X)
47 S XP="ARE YOU SURE YOU WANT TO DISASSEMBLE THIS INSTRUMENT KIT",XH="Enter 'YES' to disassemble the instrument kit, 'NO' or '^' to exit."
48 W ! I $$YN^PRCPUYN(2)'=1 D EXIT G DISASMBL
49 ;
50 S ORDERNO=$$ORDERNO^PRCPUTRX(PRCP("I"))
51 S IKITEM=0 F S IKITEM=$O(^TMP($J,"PRCPCDIR",IKITEM)) Q:'IKITEM S DATA=^(IKITEM) D
52 . K PRCPCDIK S PRCPCDIK("QTY")=$P(DATA,"^"),PRCPCDIK("INVVAL")=$J($P(DATA,"^",2),0,2),PRCPCDIK("REASON")="0:Disassembled Instrument Kit"
53 . D ITEM^PRCPUUIP(PRCP("I"),IKITEM,"S",ORDERNO,.PRCPCDIK)
54 ;
55 ; decrement instrument kit item
56 S ITEMDATA=^PRCP(445,PRCP("I"),1,ITEMDA,0),TOTVAL=$J(QUANTITY*$P(ITEMDATA,"^",22),0,2)
57 ; do not remove node 8 since other ccs may contain the ik
58 ;I $P(ITEMDATA,"^",7)=QUANTITY S TOTVAL=$P(ITEMDATA,"^",27) K ^PRCP(445,PRCP("I"),1,ITEMDA,8)
59 K PRCPCDIK S PRCPCDIK("QTY")=-QUANTITY,PRCPCDIK("INVVAL")=-TOTVAL,PRCPCDIK("REASON")="0:Disassembled Instrument Kit"
60 D ITEM^PRCPUUIP(PRCP("I"),ITEMDA,"S",ORDERNO,.PRCPCDIK)
61 D EXIT G DISASMBL
62 ;
63EXIT ; exit, unlock, clean up
64 D CLEAR^PRCPULOC(445.8,ITEMDA,0)
65 L -^PRCP(445.8,ITEMDA)
66 K ^TMP($J,"PRCPCDIR")
67 Q
Note: See TracBrowser for help on using the repository browser.