LRLABELB ;DALOI/JMC - 10 PART LABELS FOR THE INTERMEC 3000/4000 PRINTER ;8/29/94 12:36 ;;5.2;LAB SERVICE;**161,218**;Sep 27, 1994 ;This routine is used in conjunction with the Intermec program routine ;LRBARB to print a ten part 2.5X4.0 inch label. ; N CR,ETX,J,LF,LRFMT,LRLPNM,LRTXT,STX,X ; S LRTXT=$$LRTXT^LRLABLD(.LRTS,32) I LRTXT[";" S LRDTXT=".............." E S LRDTXT=LRTXT ; S LRLPNM=$P(PNM,",",1),LRLPNM=LRLPNM_$S($L(LRLPNM)<18:","_$E($P(PNM,",",2),1),1:"") ; S LRFMT=11+$G(LRBAR(+$G(LRAA))) ; Set specific symbology. I LRFMT<13 D BAR I LRFMT>12 D BAR1 ; D TERM^LRLABELA ; Q ; BAR ; Barcode label - accession number barcoded (old style). ; D INIT^LRLABELA(12) ; W STX,LRACC,CR,LRDAT,CR,LRTOP,CR,$E(PNM,1,27),CR,SSN,CR,ETX W STX,"W:",$E(LRLLOC,1,9),CR,ETX W STX,LRBARID,CR,ETX W STX,"Order #",LRCE,CR,$E(LRTXT,1,20) W:$L(LRTXT)>20 "..." W CR,ETX ; ; accession urgency I $G(LRURG0)=1 W STX,"STAT",CR,ETX E W STX,LF,CR,ETX ; W STX,LRACC,CR,LRTOP,CR,LRACC,CR,LRLPNM,CR,SSN,CR,LRDAT,CR,$S($P(LRTXT,";",1)'="":$P(LRTXT,";",1),1:LRDTXT),CR,ETX W STX,LRACC,CR,LRTOP,CR,LRACC,CR,LRLPNM,CR,SSN,CR,LRDAT,CR,$S($P(LRTXT,";",2)'="":$P(LRTXT,";",2),1:LRDTXT),CR,ETX W STX,LRACC,CR,LRDAT,CR,LRTOP,CR,$E(PNM,1,27),CR,SSN,CR,"W:",$E(LRLLOC,1,9),CR,ETX W STX,"Order #",LRCE,CR,LRTXT,CR,ETX ; ; accession urgency I $P(LRURGA,"^",2),$L($P(LRURGA,"^")) W STX,$P(LRURGA,"^"),CR,ETX E W STX,LF,CR,ETX ; W STX,LRACC,CR,LRTOP,CR,LRACC,CR,LRLPNM,CR,SSN,CR,LRDAT,CR,$S($P(LRTXT,";",1)'="":$P(LRTXT,";",1),1:LRDTXT),CR,ETX W STX,LRACC,CR,LRTOP,CR,LRACC,CR,LRLPNM,CR,SSN,CR,LRDAT,CR,$S($P(LRTXT,";",2)'="":$P(LRTXT,";",2),1:LRDTXT),CR,ETX ; Q ; BAR1 ; Barcode label (handles multiple symbologies/ specimen UID). ; D INIT^LRLABELA(13) ; W STX,LRACC,CR,LRDAT,CR,LRTOP,CR,$E(PNM,1,21),CR,SSN,CR,ETX ; ; Patient location/room bed W STX,"W:",LRLLOC,$S($L(LRRB):"/"_LRRB,1:""),CR,ETX ; ; Human-readable ID W STX,LRBARID,CR,ETX ; ; Patient info W STX,$S($G(LRINFW)="":LF,1:LRINFW),CR,ETX W STX,"Order #",LRCE,CR,LRTXT,CR,ETX ; D URGENCY^LRLABELA ; W STX,LRACC,CR,LRDAT,CR,LRACC,CR,$E(PNM,1,14),CR,SSN,CR,LRDAT,CR,ETX W STX,$S($P(LRTXT,";",1)'="":$E($P(LRTXT,";",1),1,10),1:$E(LRDTXT,1,10)),CR,ETX W STX,LRACC,CR,LRDAT,CR,LRACC,CR,$E(PNM,1,14),CR,SSN,CR,LRDAT,CR,ETX W STX,$S($P(LRTXT,";",2)'="":$P(LRTXT,";",2),1:LRDTXT),CR,ETX W STX,$E(PNM,1,21),CR,SSN,CR,ETX ; ; Patient location/room bed W STX,"W:",LRLLOC,$S($L(LRRB):"/"_LRRB,1:""),CR,ETX ; ; Human-readable ID W STX,LRBARID,CR,ETX ; ; Patient info W STX,$S($G(LRINFW)="":LF,1:LRINFW),CR,ETX ; W STX,LRTOP,CR,LRACC,CR,LRDAT,CR,"Order #",LRCE,CR,LRTXT,CR,ETX ; D URGENCY^LRLABELA ; W STX,LRACC,CR,LRDAT,CR,LRACC,CR,$E(PNM,1,14),CR,SSN,CR,LRDAT,CR,ETX W STX,$S($P(LRTXT,";",3)'="":$P(LRTXT,";",3),1:LRDTXT),CR,ETX W STX,LRACC,CR,LRDAT,CR,LRACC,CR,$E(PNM,1,14),CR,SSN,CR,LRDAT,CR,ETX W STX,$S($P(LRTXT,";",4)'="":$P(LRTXT,";",4),1:LRDTXT),CR,ETX ; ; Print appropriate barcode symbology W STX F J=13:1:15 D . ; Skip symbology . I J'=LRFMT W LF,CR,LF,CR Q . ; specimen identifier to barcode on left label. . W LRBARID,CR . ; specimen identifier to barcode on right label. . W LRBARID,CR W ETX ; Q