1 | IBDFBK2 ;ALB/AAS - AICS broker Utilities ;23-May-95
|
---|
2 | ;;3.0;AUTOMATED INFO COLLECTION SYS;;APR 24, 1997
|
---|
3 | ;
|
---|
4 | RECV(RESULT,IBD) ; -- called by broker
|
---|
5 | ; -- receives raw data array from scanning workstation and returns
|
---|
6 | ; data may come in spurs, IBD("MOREDATA") = 1 if more data pending
|
---|
7 | ;
|
---|
8 | ; errors, warnings, and expanded data.
|
---|
9 | ; Input : Result - (called by reference, see output)
|
---|
10 | ; IBD - (called by reference) contains the raw
|
---|
11 | ; data from the workstation (IBD(FD1) - IBD(FD9))
|
---|
12 | ; IB("MOREDATA") - if more data pending.
|
---|
13 | ;
|
---|
14 | ; Output: RESULT - a new array element (result(lcnt) will be
|
---|
15 | ; created for each error, warning and
|
---|
16 | ; data element received
|
---|
17 | ;
|
---|
18 | N I,J,X,Y,IBDATA,CNT,LCNT,IBDJ,INODE,ZTQUEUED,IOM,IBDF,PXCA,PXCAVSIT,ORVP,IBQUIT,SDFN,FORMID,DIE,DIC,DR,DA,DFN,D,D0,DA,DI,DK,DL,AUPNPAT,AUPNDOB,AUPNDOD,AUPNDAYS,AUPNSEX
|
---|
19 | I $D(IBD)=0 S RESULT(1)="NO DATA RECEIVED" G RECVQ
|
---|
20 | S ZTQUEUED="",IOM=80
|
---|
21 | ;
|
---|
22 | S I=""
|
---|
23 | S IBDJ=$J
|
---|
24 | I $D(IBTEST) S IBDJ=$G(IBD("IBDJ"))
|
---|
25 | F S I=$O(IBD(I)) Q:I="" S ^TMP("IBD-SCAN-RAWDATA",IBDJ,I)=IBD(I)
|
---|
26 | I $G(IBD("MOREDATA")) S RESULT(1)="PARTIAL DATA RECEIVED" G RECVQ
|
---|
27 | ;
|
---|
28 | S RESULT(1)="0^END OF DATA RECEIVED"
|
---|
29 | ;
|
---|
30 | ; -- parse strings
|
---|
31 | ; data on workstation is built into strings upto 120 characters
|
---|
32 | ; each data element delimited by a "~" and need to be parsed
|
---|
33 | ; into an array IBDATA() which is then parsed into the bubbles,
|
---|
34 | ; dynamic, and handprint arrays. IBDATA() represents data as it
|
---|
35 | ; is received from the scanner.
|
---|
36 | ;
|
---|
37 | S CNT=0
|
---|
38 | F I=1:1 S INODE="FD"_I S IBDATA=$G(^TMP("IBD-SCAN-RAWDATA",IBDJ,INODE)) Q:IBDATA="" D
|
---|
39 | . F J=1:1 S X=$P(IBDATA,"~",J) Q:X="" S CNT=CNT+1,IBDF(CNT)=X
|
---|
40 | ;
|
---|
41 | S RESULT(1)="DATA PARSED INTO FIRST ARRAY"
|
---|
42 | K IBD
|
---|
43 | ;
|
---|
44 | S RESULT(1)=$$PCE^IBDFBKR(.IBDF,.PXCA)
|
---|
45 | I $D(PXCA("ERROR")) S RESULT(1)="9^DATA REJECTED BY PCE: Critical data missing or incorrect"
|
---|
46 | I $D(PXCA("IBD-ABORT")) S RESULT(1)="9^DATA NOT SENT TO PCE"
|
---|
47 | S LCNT=1
|
---|
48 | ;
|
---|
49 | ; -- Don't try to parse array if data isn't valid
|
---|
50 | S IBQUIT=+RESULT(1),RESULT(1)=$P(RESULT(1),"^",2,99)
|
---|
51 | G:(IBQUIT<8!(IBQUIT>10)) RECVQ
|
---|
52 | D EW(.RESULT,.PXCA,.LCNT)
|
---|
53 | ;
|
---|
54 | ; -- create result array to pass back to workstation
|
---|
55 | D LSTDATA^IBDFBK3(.RESULT,.PXCA,.LCNT)
|
---|
56 | ;
|
---|
57 | I '$D(IBTEST),'$G(IBD("MOREDATA")) K ^TMP("IBD-SCAN-RAWDATA",$J)
|
---|
58 | ;remember to uncomment the line above - done 10/29/96 cmr
|
---|
59 | RECVQ I '$D(IBTEST) K PXCA,IBDF
|
---|
60 | ;I IBQUIT<8
|
---|
61 | Q
|
---|
62 | ;
|
---|
63 | EW(RESULT,PXCA,LCNT,AICS) ;
|
---|
64 | ; -- List Errors and Warning generated in PCE
|
---|
65 | ; Input : Result - (called by reference, see output)
|
---|
66 | ; PXCA - (by referencethe array of data formated to
|
---|
67 | ; the PCE device interface specification
|
---|
68 | ; lcnt - (by reference) a counter for the result array
|
---|
69 | ; Output: RESULT - a new array element result(lcnt) will be
|
---|
70 | ; created for each error and warning received
|
---|
71 | ;
|
---|
72 | N I,J,K,L,M,X,IBX
|
---|
73 | F M="ERROR","WARNING","AICS ERROR" I $D(PXCA(M)) D
|
---|
74 | .I $G(AICS),M="AICS ERROR" Q
|
---|
75 | .S I="" F S I=$O(PXCA(M,I)) Q:I="" S J="" F S J=$O(PXCA(M,I,J)) Q:J="" D
|
---|
76 | ..S K="" F S K=$O(PXCA(M,I,J,K)) Q:K="" S L="" F S L=$O(PXCA(M,I,J,K,L)) Q:L="" S IBX=$G(PXCA(M,I,J,K,L)) D
|
---|
77 | ...S X=M_": "_$P(IBX,"^")
|
---|
78 | ...I $E(X,1,4)'="AICS" S X="PCE "_X
|
---|
79 | ...I $P(IBX,"^",2)'="" S X=X_" - "_$P(IBX,"^",2)
|
---|
80 | ...I $P(IBX,"^",3)'="" S X=X_" - "_$P(IBX,"^",3)
|
---|
81 | ...I I="DIAGNOSIS/PROBLEM" S X=X_", ICD9: "_$P($G(^ICD9(+$G(PXCA(I,J,K)),0)),"^")_", "_$P($G(PXCA(I,J,K)),"^",13) I L=2,$P(PXCA(I,J,K),"^",2)="P" S $P(PXCA(I,J,K),"^",2)="S"
|
---|
82 | ...I I="ENCOUNTER",L=15 S X=X_", "_$P($G(^VA(200,+$P($G(PXCA(I)),"^",4),0)),"^") I $P(PXCA(I),"^",15)="P" S $P(PXCA(I),"^",15)="S"
|
---|
83 | ...D NEWLINE^IBDFBK3(.RESULT,X,.LCNT)
|
---|
84 | EWQ Q
|
---|
85 | ;
|
---|
86 | UNRECV(FID) ; -- used by test to un received data when testing.
|
---|
87 | ;
|
---|
88 | N IBI
|
---|
89 | I +$G(FID)<1 Q
|
---|
90 | S IBI=0 F S IBI=$O(^IBD(357.96,+FID,9,IBI)) Q:'IBI I $G(^IBD(357.96,+FID,9,IBI,0))'="" S $P(^(0),"^",2)=""
|
---|
91 | K ^IBD(357.96,+FID,10)
|
---|
92 | Q
|
---|
93 | ;
|
---|
94 | RECVERR(FORMID,ER) ; -- error occurred in ibdfbkr, store in 359.3
|
---|
95 | Q:ER<11
|
---|
96 | S DIALOG=$S(ER=11:3579610,ER=12:3579607,ER=13:3579607,ER=14:3579604,ER=15:3579606,ER=16:3579605,ER=17:3579608,ER=18:3579609,1:3570001)
|
---|
97 | S FORMID=$G(FORMID("FORMID")),FORMID("SOURCE")=1
|
---|
98 | S FORMID("APPT")=$P($G(^IBD(357.96,+$G(FORMID),0)),"^",3)
|
---|
99 | D LOGERR^IBDF18E2(DIALOG,.FORMID)
|
---|
100 | Q
|
---|
101 | ;
|
---|
102 | TESTR ;
|
---|
103 | S IBTEST="" K ALAN
|
---|
104 | S IBD("MOREDATA")=0
|
---|
105 | S IBD("IBDJ")=576718735
|
---|
106 | S FORMID=+$P($G(^TMP("IBD-SCAN-RAWDATA",IBD("IBDJ"),"FD1")),"FORMID=",2)
|
---|
107 | I +FORMID>0 D UNRECV(FORMID)
|
---|
108 | D RECV(.ALAN,.IBD)
|
---|
109 | W !! X "ZW ALAN W !! ZW PXCA"
|
---|
110 | K IBTEST
|
---|
111 | Q
|
---|