source: FOIAVistA/trunk/r/AUTOMATED_LAB_INSTRUMENTS-LA/LAMSBLD.m@ 1722

Last change on this file since 1722 was 628, checked in by George Lilly, 15 years ago

initial load of FOIAVistA 6/30/08 version

File size: 1.4 KB
Line 
1LAMSBLD ;SLC/DLG - BUILD MICROSCAN MIC X-REF IN FILE 62.06 ;7/20/90 09:48 ;
2 ;;5.2;AUTOMATED LAB INSTRUMENTS;;Sep 27, 1994
3B W "ENTER DATA FOR (A)PI, (M)ICROSCAN, OR (V)ITEK ? " R INST:DTIME W ! Q:((INST="^")!(INST=""))
4 S INST=$E(INST,1) S:"AMV"'[INST INST="?"
5 I INST="?" W !,"ENTER THE LETTER IN PARENS FOR INSTRUMENT YOU WANT TO LOAD DRUG INFORMATION ON.",! G B
6A S U="^",ZZ=0 F AS=0:0 S AS=$O(^LAB(62.06,AS)) Q:AS'>0 D SUS Q:((%<0)&(ZZ=1))
7 W !,"DONE" Q
8SUS S:'$D(^LAB(62.06,AS,1,0)) ^(0)="^62.061^^"
9 S %=2 W !,"Want to load MicroScan MIC values for ",$P(^LAB(62.06,AS,0),U) D YN^DICN Q:(%=2!(%<0))
10 I %=0 W !,"ANSWER EITHER 'NO' DO NOT LOAD THIS DRUG OR 'YES' TO LOAD." G SUS
11 S DA(1)=AS
12 I INST="A" F XX="0","0.01","0.03","0.06","0.12","0.25","0.5",1,2,4,6,8,16,32,64,128,256,512,1024,1280 S ZZ=0 W "." D LOAD Q:ZZ
13 I INST="M" F XX="0.03","0.06","0.12","0.25","0.5",1,2,4,6,8,16,32,64,128,256 S ZZ=0 W "." D LOAD Q:ZZ
14 I INST="V" F XX="0.06","0.125","0.25","0.5",1,2,4,8,16,20,32,40,64,80,128,160,256,320,500,512,640,1024,1280,2000,2560,5120,10240,20480 S ZZ=0 W "." D LOAD Q:ZZ
15 K DLAYGO
16 Q
17LOAD ;
18 S DIC(0)="MLQE",DLAYGO=62.06,DIC="^LAB(62.06,"_AS_",1,",X=XX D FILE Q:ZZ S X="<"_XX D FILE Q:ZZ S X=">"_XX D FILE Q
19FILE I $D(^LAB(62.06,AS,1,"B",X)) S Y=$O(^(X,0)) G DEF ;Already there!
20 D FILE^DICN ;MAKE A NEW ONE
21DEF S DR=".01;1//"_X,DA=+Y,(DIK,DIE)=DIC D ^DIE S:$D(Y) ZZ=1 S (DIK,DIE)=DIC D IX1^DIK Q
Note: See TracBrowser for help on using the repository browser.