source: FOIAVistA/trunk/r/AUTOMATED_LAB_INSTRUMENTS-LA/LASP120.m@ 1754

Last change on this file since 1754 was 628, checked in by George Lilly, 15 years ago

initial load of FOIAVistA 6/30/08 version

File size: 1.2 KB
Line 
1LASP120 ;SLC/RWF - VICKERS SP-120 INTERFACE FOR SMA 18/60 AUTOMATED DATA ;7/20/90 10:12 ;
2 ;;5.2;AUTOMATED LAB INSTRUMENTS;;Sep 27, 1994
3 ;CROSS LINK BY ID OR IDE
4LA1 S:$D(ZTQUEUED) ZTREQ="@" S LANM=$T(+0),TSK=$O(^LAB(62.4,"C",LANM,0)) Q:TSK<1
5 Q:'$D(^LA(TSK,"I",0))
6 K LATOP D ^LASET Q:'TSK S X="TRAP^"_LANM,@^%ZOSF("TRAP")
7LA2 S TOUT=0 D IN G QUIT:TOUT,LA2:$E(IN,9)'="/"
8 S Y(1)=IN
9 S (ID,IDE)=+$E(Y(1),3,5),V=$E(Y(1),7,8) D NUM S TRAY=+V,V=$E(Y(1),10,11) D NUM S CUP=+V
10 G LA2:'($E(Y(1),1,2)="00"!($E(Y(1),1,2)="21")!($E(Y(1),1,2)="22"))
11 F I=0:0 S I=$O(TC(I)) Q:I<1 X TC(I,2) S @TC(I,1)=V
12LA3 X LAGEN
13 F I=0:0 S I=$O(TV(I)) Q:I<1 S:TV(I,1)]"" ^LAH(LWL,1,ISQN,I)=TV(I,1)
14 G LA2
15QC ;QC TESTING HERE; S BAD=1 IF DONT STORE
16 S Y(A)=IN Q
17NUM S X="" F JJ=1:1:$L(V) S:$A(V,JJ)>32 X=X_$E(V,JJ)
18 S V=X Q
19IN S CNT=^LA(TSK,"I",0)+1 IF '$D(^(CNT)) S TOUT=TOUT+1 Q:TOUT>9 H 5 G IN
20 S ^LA(TSK,"I",0)=CNT,IN=^(CNT),TOUT=0
21 S:IN["~" CTRL=$P(IN,"~",2),IN=$P(IN,"~",1)
22 Q
23 Q
24OUT S CNT=^LA(TSK,"O")+1,^("O")=CNT,^("O",CNT)=OUT
25 LOCK ^LA("Q") S Q=^LA("Q")+1,^("Q")=Q,^("Q",Q)=TSK LOCK
26 Q
27QUIT LOCK ^LA(TSK) H 1 K ^LA(TSK),^LA("LOCK",TSK),^TMP($J),^TMP("LA",$J)
28 Q
29TRAP D ^LABERR S T=TSK D SET^LAB G @("LA2^"_LANM) ;ERROR TRAP
Note: See TracBrowser for help on using the repository browser.