1 | ENY2USRS ;(WASH CIOFO)/DH-Y2K Utility System Reports ;8.26.98
|
---|
2 | ;;7.0;ENGINEERING;**55**;August 17,1993
|
---|
3 | EN W @IOF,!,?20,"UTILITY EQUIPMENT SUMMARY REPORT"
|
---|
4 | I $P($G(^DIC(6910,1,0)),U,2)']"" W !!,"There is no STATION NUMBER in your Engineering Init Paramaters file.",!,"Can't proceed.",*7 Q
|
---|
5 | S ENSTN=0
|
---|
6 | I $P(^DIC(6910,1,0),U,10)!($D(^DIC(6910,1,3))) D I ENSTN="^" K ENSTN Q
|
---|
7 | . W !! S DIR(0)="Y",DIR("A")="Do you want a breakout by station",DIR("B")="NO"
|
---|
8 | . S DIR("?",1)="If you say 'NO' you will obtain a single report for all your equipment,"
|
---|
9 | . S DIR("?")="regardless of which station it belongs to."
|
---|
10 | . D ^DIR K DIR I $D(DIRUT) S ENSTN="^" Q
|
---|
11 | . S ENSTN=Y
|
---|
12 | W !! K IO("Q") S %ZIS="QM" D ^%ZIS G:POP EXIT
|
---|
13 | I $D(IO("Q")) S ZTRTN="SUM^ENY2USRS" D G EXIT
|
---|
14 | . S ZTDESC="Summary Util Systems Report",ZTIO=ION
|
---|
15 | . S ZTSAVE("ENSTN")=""
|
---|
16 | . D ^%ZTLOAD,HOME^%ZIS K ZTSK
|
---|
17 | ;
|
---|
18 | SUM ; summarization of utility equipment status
|
---|
19 | N STATION,COUNT,TOTAL,FMLY,COMP,DA,J,K
|
---|
20 | SUM1 S STATION("PARNT")=$P(^DIC(6910,1,0),U,2),STATION=STATION("PARNT")
|
---|
21 | F J=0,"ALARM","COMM","ELECT","ENVRN","FIRE","OTHER","SCRTY","TRANS","WATER" F K="TOT","FC","NC","CC" S COUNT(STATION,"SYS",J,K)=0,COUNT(STATION,"COMP",J,K)=0
|
---|
22 | F J=0,"ALARM","COMM","ELECT","ENVRN","FIRE","OTHER","SCRTY","TRANS","WATER" S TOTAL(STATION,"ECST",J)=0
|
---|
23 | S DA=0 F S DA=$O(^ENG(6914,"AR","BSE",DA)) Q:'DA I $D(^ENG(6914,DA,0)) D
|
---|
24 | . I '$D(ZTQUEUED),'(DA#10) W "." ; activity indicator
|
---|
25 | . Q:"^4^5^"[(U_$P($G(^ENG(6914,DA,3)),U)_U) ; turned in
|
---|
26 | . I ENSTN S STATION=$S($P($G(^ENG(6914,DA,9)),U,5)]"":$P(^(9),U,5),1:STATION("PARNT")) D:'$D(COUNT(STATION))
|
---|
27 | .. F J=0,"ALARM","COMM","ELECT","ENVRN","FIRE","OTHER","SCRTY","TRANS","WATER" F K="TOT","FC","NC","CC" S COUNT(STATION,"SYS",J,K)=0,COUNT(STATION,"COMP",J,K)=0
|
---|
28 | .. F J=0,"ALARM","COMM","ELECT","ENVRN","FIRE","OTHER","SCRTY","TRANS","WATER" S TOTAL(STATION,"ECST",J)=0
|
---|
29 | . I $P(^ENG(6914,DA,0),U,3)="" D Q
|
---|
30 | .. ;component without a parent (may or may not have children)
|
---|
31 | .. S FMLY=$P($G(^ENG(6914,DA,9)),U,12) I FMLY="" S FMLY=0
|
---|
32 | .. E S FMLY=$P($G(^ENG(6918.1,FMLY,0)),U) S:FMLY="" FMLY=0
|
---|
33 | .. S COUNT(STATION,"COMP",FMLY,"TOT")=COUNT(STATION,"COMP",FMLY,"TOT")+1,COMP("SYS")="FC" D
|
---|
34 | ... I "^FC^NA^"[(U_$P($G(^ENG(6914,DA,11)),U)_U) S COUNT(STATION,"COMP",FMLY,"FC")=COUNT(STATION,"COMP",FMLY,"FC")+1 Q
|
---|
35 | ... I $P($G(^ENG(6914,DA,11)),U)="NC" S COUNT(STATION,"COMP",FMLY,"NC")=COUNT(STATION,"COMP",FMLY,"NC")+1,COMP("SYS")="NC",TOTAL(STATION,"ECST",FMLY)=TOTAL(STATION,"ECST",FMLY)+$P($G(^ENG(6914,DA,2)),U,3) Q
|
---|
36 | ... I $P($G(^ENG(6914,DA,11)),U)="CC" S COUNT(STATION,"COMP",FMLY,"CC")=COUNT(STATION,"COMP",FMLY,"CC")+1,COMP("SYS")="NC",TOTAL(STATION,"ECST",FMLY)=TOTAL(STATION,"ECST",FMLY)+$P($G(^ENG(6914,DA,11)),U,3)
|
---|
37 | .. Q:'$D(^ENG(6914,"AE",DA)) ;no children
|
---|
38 | .. D RCRSN(DA,"")
|
---|
39 | .. S COUNT(STATION,"SYS",FMLY,"TOT")=COUNT(STATION,"SYS",FMLY,"TOT")+1
|
---|
40 | .. I COMP("SYS")]"" S COUNT(STATION,"SYS",FMLY,COMP("SYS"))=COUNT(STATION,"SYS",FMLY,COMP("SYS"))+1
|
---|
41 | ;
|
---|
42 | PRNTSUM ; print the summary report
|
---|
43 | Q:$G(ENY2K("VACO")) ; invoked by national roll-up
|
---|
44 | U IO
|
---|
45 | N PAGE,DATE,ESCAPE,UL,ULD
|
---|
46 | D NOW^%DTC S Y=% X ^DD("DD") S DATE("PRNT")=$P(Y,":",1,2),PAGE=0
|
---|
47 | S $P(UL,"-",79)="-",$P(ULD,"=",79)="="
|
---|
48 | S STATION="" F S STATION=$O(COUNT(STATION)) Q:STATION="" D HDRSUM D D HOLD Q:$G(ESCAPE)
|
---|
49 | . N PRCNT
|
---|
50 | . S COUNT(STATION,"SYS")=0,COUNT(STATION,"SYS","FC")=0,COUNT(STATION,"SYS","NC")=0 F J=0,"ALARM","COMM","ELECT","ENVRN","FIRE","OTHER","SCRTY","TRANS","WATER" D
|
---|
51 | .. S COUNT(STATION,"SYS")=COUNT(STATION,"SYS")+COUNT(STATION,"SYS",J,"TOT"),COUNT(STATION,"SYS","FC")=COUNT(STATION,"SYS","FC")+COUNT(STATION,"SYS",J,"FC")
|
---|
52 | .. S COUNT(STATION,"SYS","NC")=COUNT(STATION,"SYS","NC")+COUNT(STATION,"SYS",J,"NC")
|
---|
53 | . I 'COUNT(STATION,"SYS") W !!,?20,"<There are no Utility Systems on which to report>"
|
---|
54 | . E D
|
---|
55 | .. S PRCNT("COMP")=$P(100*(COUNT(STATION,"SYS","FC")/COUNT(STATION,"SYS"))+.5,".") S:PRCNT("COMP")="" PRCNT("COMP")=0
|
---|
56 | .. W !!,"There "_$S(COUNT(STATION,"SYS")=1:"is ",1:"are ")_COUNT(STATION,"SYS")_" Utility System"_$S(COUNT(STATION,"SYS")=1:"",1:"s")_" in this data base."
|
---|
57 | .. W !,?5,COUNT(STATION,"SYS","FC")_" ("_$J(PRCNT("COMP"),3)_" %) are Y2K compliant."
|
---|
58 | .. W:IOSL>59 !,ULD
|
---|
59 | .. W !!,?35,"SYSTEM"
|
---|
60 | .. W !,?22,"System",?40,"FC System",?60,"NC/CC System"
|
---|
61 | .. W !,"Family",?22,"Count",?42,"Count",?63,"Count"
|
---|
62 | .. W !,UL
|
---|
63 | .. F J="ALARM","COMM","ELECT","ENVRN","FIRE","OTHER","SCRTY","TRANS","WATER" W !,J,?19,$J(COUNT(STATION,"SYS",J,"TOT"),8),?39,$J(COUNT(STATION,"SYS",J,"FC"),8),?60,$J(COUNT(STATION,"SYS",J,"NC"),8)
|
---|
64 | .. W !,"No Family",?19,$J(COUNT(STATION,"SYS",0,"TOT"),8),?39,$J(COUNT(STATION,"SYS",0,"FC"),8),?60,$J(COUNT(STATION,"SYS",0,"NC"),8)
|
---|
65 | .. W:IOSL>59 !,UL
|
---|
66 | .. W !,"TOTALS",?19,$J(COUNT(STATION,"SYS"),8),?39,$J(COUNT(STATION,"SYS","FC"),8),?60,$J(COUNT(STATION,"SYS","NC"),8)
|
---|
67 | . S COUNT(STATION,"COMP")=0,COUNT(STATION,"COMP","FC")=0,COUNT(STATION,"COMP","NC")=0,COUNT(STATION,"COMP","CC")=0,TOTAL(STATION,"ECST")=0
|
---|
68 | . F J=0,"ALARM","COMM","ELECT","ENVRN","FIRE","OTHER","SCRTY","TRANS","WATER" D
|
---|
69 | .. S COUNT(STATION,"COMP")=COUNT(STATION,"COMP")+COUNT(STATION,"COMP",J,"TOT"),COUNT(STATION,"COMP","FC")=COUNT(STATION,"COMP","FC")+COUNT(STATION,"COMP",J,"FC")
|
---|
70 | .. S COUNT(STATION,"COMP","NC")=COUNT(STATION,"COMP","NC")+COUNT(STATION,"COMP",J,"NC"),COUNT(STATION,"COMP","CC")=COUNT(STATION,"COMP","CC")+COUNT(STATION,"COMP",J,"CC"),TOTAL(STATION,"ECST")=TOTAL(STATION,"ECST")+TOTAL(STATION,"ECST",J)
|
---|
71 | . I 'COUNT(STATION,"COMP") W !!,?20,"<There is no Utility Equipment on which to report>" Q
|
---|
72 | . I COUNT(STATION,"SYS"),IOSL<60 D HOLD Q:$G(ESCAPE) D HDRSUM
|
---|
73 | . I IOSL>59 W !!,ULD
|
---|
74 | . W !,?34,"COMPONENTS"
|
---|
75 | . W !,?12,"Component",?24,"FC Component",?39,"NC Component",?54,"CC Component",?69,"Est Comp"
|
---|
76 | . W !,"Family",?14,"Count",?28,"Count",?43,"Count",?58,"Count",?71,"Cost"
|
---|
77 | . W !,UL
|
---|
78 | . F J="ALARM","COMM","ELECT","ENVRN","FIRE","OTHER","SCRTY","TRANS","WATER" W !,J,?12,$J(COUNT(STATION,"COMP",J,"TOT"),8),?27,$J(COUNT(STATION,"COMP",J,"FC"),8),?42,$J(COUNT(STATION,"COMP",J,"NC"),8),?57,$J(COUNT(STATION,"COMP",J,"CC"),8) D
|
---|
79 | .. W ?67,"$",$J($P(TOTAL(STATION,"ECST",J)+.5,"."),9,0)
|
---|
80 | . W !,"No Family",?12,$J(COUNT(STATION,"COMP",0,"TOT"),8),?27,$J(COUNT(STATION,"COMP",0,"FC"),8),?42,$J(COUNT(STATION,"COMP",0,"NC"),8),?57,$J(COUNT(STATION,"COMP",0,"CC"),8),?67,"$",$J($P(TOTAL(STATION,"ECST",0)+.5,"."),9,0)
|
---|
81 | . W !,UL
|
---|
82 | . W !,"TOTALS",?12,$J(COUNT(STATION,"COMP"),8),?27,$J(COUNT(STATION,"COMP","FC"),8),?42,$J(COUNT(STATION,"COMP","NC"),8),?57,$J(COUNT(STATION,"COMP","CC"),8),?67,"$",$J($P(TOTAL(STATION,"ECST")+.5,"."),9,0)
|
---|
83 | . W !,ULD
|
---|
84 | G EXIT ; design exit for summary report
|
---|
85 | ;
|
---|
86 | HDRSUM ; header for summary utility systems report
|
---|
87 | Q:$G(ESCAPE)
|
---|
88 | W:PAGE>0!($E(IOST,1,2)="C-") @IOF S PAGE=PAGE+1
|
---|
89 | W "Summary Report on Utility Equipment as of "_DATE("PRNT"),?70,"Page: "_PAGE
|
---|
90 | W !,$S(ENSTN:"Station: "_STATION,1:"Consolidated ("_STATION("PARNT")_")")
|
---|
91 | W !,ULD
|
---|
92 | Q
|
---|
93 | ;
|
---|
94 | RCRSN(PARNT,PRECRSR) ; build hierarchical system tree
|
---|
95 | N CHILD
|
---|
96 | S CHILD=0 F S CHILD=$O(^ENG(6914,"AE",PARNT,CHILD)) Q:'CHILD D
|
---|
97 | . Q:","_PRECRSR_PARNT_","[(","_CHILD_",") ; would be an endless loop
|
---|
98 | . Q:"^4^5^"[(U_$P($G(^ENG(6914,CHILD,3)),U)_U) ; ck for turn-ins
|
---|
99 | . S COUNT(STATION,"COMP",FMLY,"TOT")=COUNT(STATION,"COMP",FMLY,"TOT")+1 D
|
---|
100 | .. I "^FC^NA^"[(U_$P($G(^ENG(6914,DA,11)),U)_U) S COUNT(STATION,"COMP",FMLY,"FC")=COUNT(STATION,"COMP",FMLY,"FC")+1 Q
|
---|
101 | .. I $P($G(^ENG(6914,DA,11)),U)="NC" S COUNT(STATION,"COMP",FMLY,"NC")=COUNT(STATION,"COMP",FMLY,"NC")+1,COMP("SYS")="NC",TOTAL(STATION,"ECST",FMLY)=TOTAL(STATION,"ECST",FMLY)+$P($G(^ENG(6914,DA,2)),U,3) Q
|
---|
102 | .. I $P($G(^ENG(6914,DA,11)),U)="CC" S COUNT(STATION,"COMP",FMLY,"CC")=COUNT(STATION,"COMP",FMLY,"CC")+1,COMP("SYS")="NC",TOTAL(STATION,"ECST",FMLY)=TOTAL(STATION,"ECST",FMLY)+$P($G(^ENG(6914,DA,11)),U,3) Q
|
---|
103 | .. ;this component has Y2K category of null
|
---|
104 | .. S:COMP("SYS")'="NC" COMP("SYS")=""
|
---|
105 | . I $O(^ENG(6914,"AE",CHILD,0)) D RCRSN(CHILD,PRECRSR_PARNT_",")
|
---|
106 | Q
|
---|
107 | ;
|
---|
108 | HOLD Q:$E(IOST,1,2)'="C-"!($G(ESCAPE))
|
---|
109 | W !!,"Press <RETURN> to continue, '^' to escape..." R X:DTIME
|
---|
110 | I '$T!($E(X)="^") S ESCAPE=1
|
---|
111 | Q
|
---|
112 | ;
|
---|
113 | EXIT K ENSTN
|
---|
114 | I $D(ZTQUEUED) S ZTREQN="@"
|
---|
115 | D ^%ZISC,HOME^%ZIS
|
---|
116 | Q
|
---|
117 | ;ENY2USRS
|
---|