1PRCNENG ;SSI/SEB-Engineering display/entry ;[ 07/19/96 2:33 PM ]
2 ;;1.0;Equipment/Turn-In Request;;Sep 13, 1996
3REV ; Review equipment requests
4 S DIC("S")="I $P(^(0),U,7)=8!($P(^(0),U,7)=26)!($P(^(0),U,7)=30)"
5 S DIC="^PRCN(413,",DIC(0)="AEQZ" D ^DIC K DIC("S") G EXIT1:Y<0
6 S DIE("NO^")="BACKOUTOK"
7 S (IN,DA)=+Y,PRCNUSR=2,DIE=DIC,DIE("NO^")="OUTOK",DR="[PRCNENG]",SP=$G(^PRCN(413,DA,2))
8 D SETUP^PRCNPRNT,ROOM:$P(SP,U,10)="Y"&($P(SP,U,19)="")
9 S %=1 W !!,"Do you wish to edit this transaction" D YN^DICN S PRCNEA=%
10 S STAT=$P(^PRCN(413,IN,0),U,7)
11 I STAT=30,PRCNEA=2 D ESIG G EXIT
12 I PRCNEA=1 D ^DIE
13EXIT K DIC,DIE,DA,DR,IN,PRCNUSR,SP,Y,%,D,D0,FAIL,STAT,C,CON,PROJ,J,%,PRCNEA
14 G REV
15EXIT1 K DIC
16 Q
17ROOM ; Inform engineer if space available and room not in space file
18 W $C(7),!!,"LOCATION: ",$P(SP,U,11)," is not in the Space File..."
19 Q
20ESIG ; Electronic signature
21 D ES^PRCNUTL
22 I $G(FAIL)<1 K FAIL Q
23 S DR="6////^S X=27;7////^S X=DT" D ^DIE
24 W !!,"Transaction returned to PPM"
25 Q
26VEN ; Get and display vendor
27 S VEN=$P($G(^PRCN(413,D0,7)),U,16) S:VEN'="" VEN=$P(^PRC(440,VEN,0),U)
28 S VEN=$S($G(VEN)="":$P($G(^PRCN(413,D0,7)),U,4),1:VEN)
29 Q
30LOC ; Get and display location
31 S LOC=$P($G(^PRCN(413,D0,2)),U,19) S:LOC'="" LOC=$P(^ENG("SP",LOC,0),U)
32 S LOC=$S($G(LOC)="":$P($G(^PRCN(413,D0,2)),U,11),1:LOC)
33 Q