MAGDLBAA ;WOIFO/LB - Routine to move failed dicom images to ^MAG(2006.575 ; 03/08/2005 07:04 ;;3.0;IMAGING;**11,51**;26-August-2005 ;; +---------------------------------------------------------------+ ;; | Property of the US Government. | ;; | No permission to copy or redistribute this software is given. | ;; | Use of unreleased versions of this software requires the user | ;; | to execute a written test agreement with the VistA Imaging | ;; | Development Office of the Department of Veterans Affairs, | ;; | telephone (301) 734-0100. | ;; | | ;; | The Food and Drug Administration classifies this software as | ;; | a medical device. As such, it may not be changed in any way. | ;; | Modifications to this software may result in an adulterated | ;; | medical device under 21CFR820, the use of which is considered | ;; | to be a violation of US Federal Statutes. | ;; +---------------------------------------------------------------+ ;; Q MOVE ;called from MAGDIR1 to move entries not matching Radiology case #. ;Not done thru FM because the system should be independent. ;These variable are needed to be defined before using this routine: ;PIDCHECK, FIRSTDCM, IMGSVC, MIDCM, MACHID,ACNUMB, CASENUMB, PNAMEDCM, PID ;MODALITY, CASETEXT N DATE,REASON,IEN,NIEN,ORIG,DCMPNME,CASE,CASENUM,PATIENT D NOW^%DTC S DATE=X ;ADD ENTRY L +^MAGD(2006.575,0):1E9 ; Background process MUST wait S X=$G(^MAGD(2006.575,0)) S $P(X,"^",1,2)="DICOM FAILED IMAGES^2006.575" S IEN=$O(^MAGD(2006.575," "),-1)+1,$P(X,"^",3)=IEN S $P(X,"^",4)=$P(X,"^",4)+1 ; # entries S ^MAGD(2006.575,0)=X ; S REASON=$P(PIDCHECK,",",2) S PATIENT=LASTDCM_","_FIRSTDCM_$S($L(MIDCM)>0:" "_MIDCM,1:"") S MACHID=$G(MACHID,"A") ; PNAMEDCM usually contains an "^" between last & first name ; CHANGE ^ TO ~ S CASE=$TR(ACNUMB,"^","~"),CASENUM=$TR(CASENUMB,"^","~") S DCMPNME=$TR(PNAMEDCM,"^","~") S ^MAGD(2006.575,IEN,0)=FROMPATH_"^"_REASON_"^"_PID_"^"_PATIENT_"^"_DCMPNME S ^MAGD(2006.575,IEN,1)=CASE_"^"_CASENUM_"^"_DATE_"^"_MACHID_"^"_LOCATION S ^MAGD(2006.575,IEN,"AIUID")=$G(IMAGEUID) S ^MAGD(2006.575,IEN,"ASUID")=STUDYUID S ^MAGD(2006.575,IEN,"AMFG")=$G(INSTNAME)_"^"_$G(ROWS)_"^"_$G(COLUMNS)_"^"_$G(OFFSET)_"^"_$G(MODIEN)_"^"_$G(MODALITY)_"^"_$$UP^MAGDFCNV($G(MFGR))_"^"_$$UP^MAGDFCNV($G(MODEL))_"^"_LOCATION S ^MAGD(2006.575,IEN,"ACSTXT")=$G(CASETEXT) ; Image type can be RAD, MEDICINE, SURGERY, etc. S ^MAGD(2006.575,IEN,"TYPE")=$G(IMGSVC) ;Setting xrefs S ^MAGD(2006.575,"B",FROMPATH,IEN)="" ; Clean up---no longer need this cross reference K ^MAGD(2006.575,"D") ; Used for Consults only L -^MAGD(2006.575,0) ; ;The following xref ("F") will be set on the 1st entry having a unique ;STUDYUID. The remaining entries with the same # will be added ;to the RELATED IMAGES multiple field for the entry that set the ;F xref. S ORIG=0 I '$D(^MAGD(2006.575,"F",LOCATION,STUDYUID)) D Q ; Quit if 1st entry . S ^MAGD(2006.575,"F",LOCATION,STUDYUID,IEN)="" . Q S ORIG=$O(^MAGD(2006.575,"F",LOCATION,STUDYUID,0)) Q:'ORIG I ORIG'=IEN D . I '$D(^MAGD(2006.575,ORIG,"RLATE",0)) D . . S ^MAGD(2006.575,ORIG,"RLATE",0)="^2006.57526PA^^" . S NIEN=$P(^MAGD(2006.575,ORIG,"RLATE",0),"^",3),NIEN=NIEN+1 . S $P(^MAGD(2006.575,ORIG,"RLATE",0),"^",3)=NIEN ; #next ien entry . S $P(^MAGD(2006.575,ORIG,"RLATE",0),"^",4)=$P(^MAGD(2006.575,ORIG,"RLATE",0),"^",4)+1 ; #record for multiple field . S ^MAGD(2006.575,ORIG,"RLATE",NIEN,0)=IEN . S ^MAGD(2006.575,ORIG,"RLATE","B",IEN,NIEN)="" . Q Q ;