1OCXDI01A ;SLC/RJS,CLA - OCX PACKAGE DIAGNOSTIC ROUTINES ;SEP 7,1999 at 10:30
2 ;;3.0;ORDER ENTRY/RESULTS REPORTING;**32**;Dec 17,1997
3 ;; ;;ORDER CHECK EXPERT version 1.01 released OCT 29,1998
4 ;
5S ;
6 ;
7 D DOT^OCXDIAG
8 ;
9 ;
10 K REMOTE,LOCAL,OPCODE,REF
11 F LINE=1:1:500 S TEXT=$P($T(DATA+LINE),";",2,999) Q:TEXT I $L(TEXT) D Q:QUIT
12 .S ^TMP("OCXDIAG",$J,$O(^TMP("OCXDIAG",$J,"A"),-1)+1)=TEXT
13 ;
14 G ^OCXDI01B
15 ;
16 Q
17 ;
18DATA ;
19 ;
20 ;;EOR^
21 ;;KEY^864.1:^LINE TAG
22 ;;R^"864.1:",.01,"E"
23 ;;D^LINE TAG
24 ;;R^"864.1:",.02,"E"
25 ;;D^TAG
26 ;;R^"864.1:",2,"E"
27 ;;D^FREE TEXT
28 ;;R^"864.1:","864.11:1",.01,"E"
29 ;;D^QUERY
30 ;;R^"864.1:","864.11:1",1,"E"
31 ;;D^Entry reference (e.g., TAG^ROUTINE)
32 ;;R^"864.1:","864.11:3",.01,"E"
33 ;;D^HELP MESSAGE
34 ;;R^"864.1:","864.11:3",1,"E"
35 ;;D^Must be a valid entry reference such as 'XXX^YYYY' or '^ZZZZ'. Note that the routine name must always be specified. This reference does not need to exist yet.
36 ;;R^"864.1:","864.11:5",.01,"E"
37 ;;D^DIALOGUE VALIDATION CODE
38 ;;R^"864.1:","864.11:5",1,"E"
39 ;;D^TAG^OCXFDFTE
40 ;;R^"864.1:","864.11:6",.01,"E"
41 ;;D^VALUE CALL
42 ;;R^"864.1:","864.11:6",1,"E"
43 ;;D^FT^OCXFDFT
44 ;;R^"864.1:","864.11:7",.01,"E"
45 ;;D^REPEAT THE QUERY
46 ;;R^"864.1:","864.11:7",1,"E"
47 ;;D^0
48 ;;R^"864.1:","864.11:8",.01,"E"
49 ;;D^LOOP QUERY
50 ;;R^"864.1:","864.11:8",1,"E"
51 ;;D^Enter another entry reference
52 ;;EOR^
53 ;;KEY^864.1:^ENTRY REFERENCE
54 ;;R^"864.1:",.01,"E"
55 ;;D^ENTRY REFERENCE
56 ;;R^"864.1:",.02,"E"
57 ;;D^ENT REF
58 ;;R^"864.1:",2,"E"
59 ;;D^FREE TEXT
60 ;;R^"864.1:","864.11:1",.01,"E"
61 ;;D^QUERY
62 ;;R^"864.1:","864.11:1",1,"E"
63 ;;D^Entry reference (e.g., TAG^ROUTINE)
64 ;;R^"864.1:","864.11:2",.01,"E"
65 ;;D^HELP MESSAGE
66 ;;R^"864.1:","864.11:2",1,"E"
67 ;;D^Must be a valid entry reference such as 'XXX^YYYY' or '^ZZZ'. Note that the routine name must always be specified. The reference must actually exist to be validated.
68 ;;R^"864.1:","864.11:4",.01,"E"
69 ;;D^DIALOGUE VALIDATION CODE
70 ;;R^"864.1:","864.11:4",1,"E"
71 ;;D^EREF^OCXFDFTE
72 ;;EOR^
73 ;;KEY^864.1:^CODE STRING
74 ;;R^"864.1:",.01,"E"
75 ;;D^CODE STRING
76 ;;R^"864.1:",.02,"E"
77 ;;D^CODE
78 ;;R^"864.1:",2,"E"
79 ;;D^FREE TEXT
80 ;;R^"864.1:","864.11:1",.01,"E"
81 ;;D^QUERY
82 ;;R^"864.1:","864.11:1",1,"E"
83 ;;D^Enter a "Set of Codes" string
84 ;;R^"864.1:","864.11:2",.01,"E"
85 ;;D^HELP MESSAGE
86 ;;R^"864.1:","864.11:2",1,"E"
87 ;;D^This must be a valid FileMan "Set of Codes" string using the ";" and ":" delimeters; e.g., "1:YES;0:NO". The maximum string length is 240 characters.
88 ;;R^"864.1:","864.11:5",.01,"E"
89 ;;D^DIALOGUE VALIDATION CODE
90 ;;R^"864.1:","864.11:5",1,"E"
91 ;;D^SCODE^OCXFDFTE
92 ;;R^"864.1:","864.11:6",.01,"E"
93 ;;D^ERROR MESSAGE
94 ;;R^"864.1:","864.11:6",1,"E"
95 ;;D^This must be a valid FileMan "Set of Codes" string using the ";" and ":" delimiters; e.g., "1:YES;0:NO". The maximum string length is 240 characters.
96 ;;R^"864.1:","864.11:7",.01,"E"
97 ;;D^VALUE CALL
98 ;;R^"864.1:","864.11:7",1,"E"
99 ;;D^CS^OCXFDCS
100 ;;R^"864.1:","864.11:8",.01,"E"
101 ;;D^REPEAT THE QUERY
102 ;;R^"864.1:","864.11:8",1,"E"
103 ;;D^0
104 ;;EOR^
105 ;;KEY^864.1:^OPEN REFERENCE
106 ;;R^"864.1:",.01,"E"
107 ;;D^OPEN REFERENCE
108 ;;R^"864.1:",.02,"E"
109 ;;D^OREF
110 ;;R^"864.1:",2,"E"
111 ;;D^FREE TEXT
112 ;;R^"864.1:","864.11:1",.01,"E"
113 ;;D^QUERY
114 ;;R^"864.1:","864.11:1",1,"E"
115 ;;D^Enter a valid open reference
116 ;;R^"864.1:","864.11:2",.01,"E"
117 ;;D^HELP MESSAGE
118 ;;R^"864.1:","864.11:2",1,"E"
119 ;;D^An open reference has the format ^X(3, or ^ZZZ( or the local variable equivalent
120 ;;R^"864.1:","864.11:3",.01,"E"
121 ;;D^DIALOGUE VALIDATION CODE
122 ;;R^"864.1:","864.11:3",1,"E"
123 ;;D^OREF^OCXFDFTE
124 ;;EOR^
125 ;;KEY^864.1:^CLOSED REFERENCE
126 ;;R^"864.1:",.01,"E"
127 ;;D^CLOSED REFERENCE
128 ;;R^"864.1:",.02,"E"
129 ;;D^CREF
130 ;;R^"864.1:",2,"E"
131 ;;D^FREE TEXT
132 ;;R^"864.1:","864.11:1",.01,"E"
133 ;;D^QUERY
134 ;;R^"864.1:","864.11:1",1,"E"
135 ;;D^Enter a local or global reference
136 ;;R^"864.1:","864.11:2",.01,"E"
137 ;;D^HELP MESSAGE
138 ;;R^"864.1:","864.11:2",1,"E"
139 ;;D^This is a full local or global reference; e.g., ^XXX(3,5) or ^XXX or VAR(4) or VAR.
140 ;;R^"864.1:","864.11:4",.01,"E"
141 ;;D^DIALOGUE VALIDATION CODE
142 ;;R^"864.1:","864.11:4",1,"E"
143 ;;D^CREF^OCXFDFTE
144 ;;R^"864.1:","864.11:5",.01,"E"
145 ;;D^VALUE CALL
146 ;;R^"864.1:","864.11:5",1,"E"
147 ;;D^FT^OCXFDFT
148 ;;R^"864.1:","864.11:6",.01,"E"
149 ;;D^REPEAT THE QUERY
150 ;;R^"864.1:","864.11:6",1,"E"
151 ;;D^0
152 ;;R^"864.1:","864.11:7",.01,"E"
153 ;;D^LOOP QUERY
154 ;;R^"864.1:","864.11:7",1,"E"
155 ;;D^Enter another closed reference
156 ;;EOR^
157 ;;KEY^864.1:^FILEMAN DD LOCATION
158 ;;R^"864.1:",.01,"E"
159 ;;D^FILEMAN DD LOCATION
160 ;;R^"864.1:",.02,"E"
161 ;;D^FM DD
162 ;;R^"864.1:",2,"E"
163 ;;D^FREE TEXT
164 ;;R^"864.1:","864.11:1",.01,"E"
165 ;;D^QUERY
166 ;;R^"864.1:","864.11:1",1,"E"
167 ;;D^Enter Data Dictionary location ("file#,field#")
168 ;;R^"864.1:","864.11:2",.01,"E"
169 ;;D^HELP MESSAGE
170 ;;R^"864.1:","864.11:2",1,"E"
171 ;;D^This text string must have the following format: a valid FileMan file number followed by a comma followed by a valid field number for the file.
172 ;;R^"864.1:","864.11:5",.01,"E"
173 ;;D^DIALOGUE VALIDATION CODE
174 ;;R^"864.1:","864.11:5",1,"E"
175 ;;D^FMDD^OCXFDFTE
176 ;;EOR^
177 ;;KEY^864.1:^POSITIVE INTEGER
178 ;1;
179 ;
Note: See TracBrowser for help on using the repository browser.