| 1 | ORQQVI2 ;SLC/dee- RPC calls to GMRVPCE0, Vitals data event drivers ;2/2/98
 | 
|---|
| 2 |  ;;3.0;ORDER ENTRY/RESULTS REPORTING;**10**;Dec 17, 1997
 | 
|---|
| 3 |  ;
 | 
|---|
| 4 |  Q
 | 
|---|
| 5 |  ;
 | 
|---|
| 6 |  ; ORQDATA is in the format
 | 
|---|
| 7 |  ;   ORQDATA(i)="VST^DT^encounter date"                       required
 | 
|---|
| 8 |  ;   ORQDATA(i)="VST^PT^pointer to patient"                   required
 | 
|---|
| 9 |  ;   ORQDATA(i)="VST^HL^pointer to Hospital Location"         required
 | 
|---|
| 10 |  ;   ORQDATA(i)="VIT^vital type^^^value^provider^units^date/time"
 | 
|---|
| 11 |  ; ORVITALS is the array passed to GMRV in the PCE Device Interface
 | 
|---|
| 12 |  ;   format.
 | 
|---|
| 13 |  ; ORQVIT is an array subscipted by the index in ORVITALS that contains
 | 
|---|
| 14 |  ;   the subscript of the data gotten from ORQDATA.  This is used to tell
 | 
|---|
| 15 |  ;   the caller which item had an ERROR or WARNING.
 | 
|---|
| 16 |  ; ORRETURN(0) is 1 if no ERRORs or WARNINGs
 | 
|---|
| 17 |  ;              0 if there are WARNING(s) but no ERRORs
 | 
|---|
| 18 |  ;             -1 if there are ERROR(s)
 | 
|---|
| 19 |  ; ORRETURN(n) where n>0 is an error or warning in validating the data
 | 
|---|
| 20 |  ;   1 piece:  subscript of ORQDATA that the error or warning is on
 | 
|---|
| 21 |  ;   2 piece:  "ERROR" or "WARNING"
 | 
|---|
| 22 |  ;   3 piece:  text message about error or warning
 | 
|---|
| 23 |  ;   4 piece:  data item that generated the error or warning
 | 
|---|
| 24 |  ;
 | 
|---|
| 25 | VALIDATE(ORRETURN,ORQDATA) ;
 | 
|---|
| 26 |  ; Given the array ORQDATA passed in by PCE Device Interface whose
 | 
|---|
| 27 |  ; format is described in the PCE Device Interface documentation, this
 | 
|---|
| 28 |  ; procedure will validate the Vitals data.  If the data is invalid,
 | 
|---|
| 29 |  ; the procedure will return the errors in the form given above.
 | 
|---|
| 30 |  ;
 | 
|---|
| 31 |  N ORVITALS,ORQVIT
 | 
|---|
| 32 |  ;Initialize RETURN to no errors
 | 
|---|
| 33 |  K ORRETURN
 | 
|---|
| 34 |  S ORRETURN(0)=1
 | 
|---|
| 35 |  D PREVITAL(.ORRETURN,.ORVITALS,.ORQVIT,.ORQDATA)
 | 
|---|
| 36 |  D VALIDATE^GMRVPCE0(.ORVITALS)
 | 
|---|
| 37 |  D POSTVIT(.ORRETURN,.ORQVIT,.ORVITALS)
 | 
|---|
| 38 |  Q
 | 
|---|
| 39 |  ;
 | 
|---|
| 40 | VALSTORE(ORRETURN,ORQDATA) ;Calls VALIDATE and if no errors calls STORE
 | 
|---|
| 41 |  ; Given the array ORQDATA passed in by PCE Device Interface whose
 | 
|---|
| 42 |  ; format is described in the PCE Device Interface documentation, this
 | 
|---|
| 43 |  ; procedure will validate the Vitals data.  If the data is invalid,
 | 
|---|
| 44 |  ; the procedure will return the errors in the form given above.
 | 
|---|
| 45 |  ; If there are no errors then this procedure will call 
 | 
|---|
| 46 |  ; Vitals/Measurements to store the data in the GMRV's 
 | 
|---|
| 47 |  ; Patient Measurements (120.5) file.
 | 
|---|
| 48 |  ;
 | 
|---|
| 49 |  N ORVITALS,ORQVIT
 | 
|---|
| 50 |  ;Initialize RETURN to no errors
 | 
|---|
| 51 |  K ORRETURN
 | 
|---|
| 52 |  S ORRETURN(0)=1
 | 
|---|
| 53 |  D PREVITAL(.ORRETURN,.ORVITALS,.ORQVIT,.ORQDATA)
 | 
|---|
| 54 |  D VALIDATE^GMRVPCE0(.ORVITALS)
 | 
|---|
| 55 |  D POSTVIT(.ORRETURN,.ORQVIT,.ORVITALS)
 | 
|---|
| 56 |  I ORRETURN(0)=1 D STORE^GMRVPCE0(.ORVITALS)
 | 
|---|
| 57 |  Q
 | 
|---|
| 58 |  ;
 | 
|---|
| 59 | PREVITAL(ORRETURN,ORVITALS,ORQVIT,ORQDATA) ;format array for call to Vitlals
 | 
|---|
| 60 |  N ORQTYPE,ORQCODE,ORINDEX1,ORINDEX2,ORRETINX,ORQITEM
 | 
|---|
| 61 |  N ORQNODT,ORQNOPT,ORQNOHL
 | 
|---|
| 62 |  S (ORQNODT,ORQNOPT,ORQNOHL)=1
 | 
|---|
| 63 |  S ORVITALS("SOURCE")="^"_DUZ
 | 
|---|
| 64 |  S ORINDEX2=0
 | 
|---|
| 65 |  S ORRETINX=$O(ORRETURN(""),-1)
 | 
|---|
| 66 |  S ORINDEX1=""
 | 
|---|
| 67 |  F  S ORINDEX1=$O(ORQDATA(ORINDEX1)) Q:'ORINDEX1  D
 | 
|---|
| 68 |  . S ORQDATAX=ORQDATA(ORINDEX1),ORQTYPE=$P(ORQDATAX,"^"),ORQCODE=$P(ORQDATAX,"^",2)
 | 
|---|
| 69 |  . I ORQTYPE="PRV" S ORVITALS("PROVIDER",1)=ORQCODE Q
 | 
|---|
| 70 |  . I ORQTYPE="VST" D  Q
 | 
|---|
| 71 |  .. I ORQCODE="DT" D  Q
 | 
|---|
| 72 |  ... S ORQNODT=0
 | 
|---|
| 73 |  ... S ORQITEM=$P(ORQDATAX,"^",3)
 | 
|---|
| 74 |  ... S $P(ORVITALS("ENCOUNTER"),"^",1)=ORQITEM
 | 
|---|
| 75 |  ... I ORQITEM>$$NOW^XLFDT D
 | 
|---|
| 76 |  .... S ORRETINX=ORRETINX+1
 | 
|---|
| 77 |  .... S ORRETURN(ORRETINX)=ORINDEX1_"^ERROR^Date/Time entered cannot be in the future^"_$$FMTE^XLFDT(ORQITEM)
 | 
|---|
| 78 |  .... S ORRETURN(0)=-1
 | 
|---|
| 79 |  ... I ORQITEM'>1800000 D
 | 
|---|
| 80 |  .... S ORRETINX=ORRETINX+1
 | 
|---|
| 81 |  .... S ORRETURN(ORRETINX)=ORINDEX1_"^ERROR^Encounter Date/Time not valid^"_ORQITEM
 | 
|---|
| 82 |  .... S ORRETURN(0)=-1
 | 
|---|
| 83 |  .. I ORQCODE="PT" D  Q
 | 
|---|
| 84 |  ... S ORQNOPT=0
 | 
|---|
| 85 |  ... S ORQITEM=$P(ORQDATAX,"^",3)
 | 
|---|
| 86 |  ... S $P(ORVITALS("ENCOUNTER"),"^",2)=ORQITEM
 | 
|---|
| 87 |  ... I '($D(^DPT(+ORQITEM,0))#2) D
 | 
|---|
| 88 |  .... S ORRETINX=ORRETINX+1
 | 
|---|
| 89 |  .... S ORRETURN(ORRETINX)=ORINDEX1_"^ERROR^Patient missing or invalid in file 2^"_ORQITEM
 | 
|---|
| 90 |  .... S ORRETURN(0)=-1
 | 
|---|
| 91 |  .. I ORQCODE="HL" D  Q
 | 
|---|
| 92 |  ... S ORQNOHL=0
 | 
|---|
| 93 |  ... S ORQITEM=$P(ORQDATAX,"^",3)
 | 
|---|
| 94 |  ... S $P(ORVITALS("ENCOUNTER"),"^",3)=ORQITEM
 | 
|---|
| 95 |  ... I '$D(^SC(ORQITEM,0)) D
 | 
|---|
| 96 |  .... S ORRETINX=ORRETINX+1
 | 
|---|
| 97 |  .... S ORRETURN(ORRETINX)=ORINDEX1_"^ERROR^HOSPITAL LOCATION Missing is not in file 44^"_ORQITEM
 | 
|---|
| 98 |  .... S ORRETURN(0)=-1
 | 
|---|
| 99 |  ...; I $D(^PX(815,1,"DHL","B",ORQITEM)) D
 | 
|---|
| 100 |  ...;. S ORRETINX=ORRETINX+1
 | 
|---|
| 101 |  ...;. S ORRETURN(ORRETINX)=ORINDEX1_"^ERROR^HOSPITAL LOCATION Can not be a disposition clinic^"_ORQITEM
 | 
|---|
| 102 |  ...;. S ORRETURN(0)=-1
 | 
|---|
| 103 |  . I ORQTYPE="VIT" D  Q
 | 
|---|
| 104 |  .. S ORINDEX2=ORINDEX2+1
 | 
|---|
| 105 |  .. S ORQVIT(ORINDEX2)=ORINDEX1
 | 
|---|
| 106 |  .. S ORVITALS("VITALS",+$P(ORQDATAX,"^",6),ORINDEX2)=ORQCODE_"^"_$P(ORQDATAX,"^",5)_"^"_$P(ORQDATAX,"^",7,8)
 | 
|---|
| 107 |  I ORQNODT D
 | 
|---|
| 108 |  . S ORRETINX=ORRETINX+1
 | 
|---|
| 109 |  . S ORRETURN(ORRETINX)="^ERROR^Required data item, ENCOUNTER DATE/TIME, is missing^"
 | 
|---|
| 110 |  . S ORRETURN(0)=-1
 | 
|---|
| 111 |  I ORQNOPT D
 | 
|---|
| 112 |  . S ORRETINX=ORRETINX+1
 | 
|---|
| 113 |  . S ORRETURN(ORRETINX)="^ERROR^Required data item, PATIENT, is missing^"
 | 
|---|
| 114 |  . S ORRETURN(0)=-1
 | 
|---|
| 115 |  I ORQNOHL D
 | 
|---|
| 116 |  . S ORRETINX=ORRETINX+1
 | 
|---|
| 117 |  . S ORRETURN(ORRETINX)="^ERROR^Required data item, HOSPITAL LOCATION, is missing^"
 | 
|---|
| 118 |  . S ORRETURN(0)=-1
 | 
|---|
| 119 |  Q
 | 
|---|
| 120 |  ;
 | 
|---|
| 121 | POSTVIT(ORRETURN,ORQVIT,ORVITALS) ;return errors and warnings
 | 
|---|
| 122 |  N ORVAR,ORINDEX,ORQTYPE
 | 
|---|
| 123 |  S ORINDEX=$O(ORRETURN(""),-1)
 | 
|---|
| 124 |  F ORQTYPE="WARNING","ERROR" D
 | 
|---|
| 125 |  . S ORVAR="ORVITALS("""_ORQTYPE_""")"
 | 
|---|
| 126 |  . F  S ORVAR=$Q(@ORVAR) Q:ORVAR'[("ORVITALS("""_ORQTYPE_"""")  D
 | 
|---|
| 127 |  .. S ORINDEX=ORINDEX+1
 | 
|---|
| 128 |  .. S ORRETURN(ORINDEX)=$G(ORQVIT($P(ORVAR,",",4)))_"^"_ORQTYPE_"^"_@ORVAR
 | 
|---|
| 129 |  .. I ORQTYPE="WARNING" S:ORRETURN(0)>0 ORRETURN(0)=0
 | 
|---|
| 130 |  .. E  S ORRETURN(0)=-1
 | 
|---|
| 131 |  Q
 | 
|---|
| 132 |  ;
 | 
|---|
| 133 | HELP(ORQLST,ORQTYPE) ; This procedure will return help for a particular
 | 
|---|
| 134 |  ; measurement type in an array.
 | 
|---|
| 135 |  ;   Input
 | 
|---|
| 136 |  ;   Variables:  ORQTYPE=Type of measurement (abbreviation
 | 
|---|
| 137 |  ;               (req.)  from PCE Device Interface Specification).
 | 
|---|
| 138 |  ;               ORQLST=Array root to store help text in
 | 
|---|
| 139 |  ;
 | 
|---|
| 140 |  D HELP^GMRVPCE0(ORQTYPE,"ORQLST")
 | 
|---|
| 141 |  Q
 | 
|---|
| 142 |  ;
 | 
|---|
| 143 | RATECHK(ORRETURN,ORQTYPE,ORQRATE,ORQUNIT) ;
 | 
|---|
| 144 |  ; Extrinsic function to validate the
 | 
|---|
| 145 |  ; rate for a particular measurement
 | 
|---|
| 146 |  ;   Input
 | 
|---|
| 147 |  ;   Variables:  ORQTYPE=Type of measurement (abbreviation
 | 
|---|
| 148 |  ;               (req.)  from PCE Device Interface Specification).
 | 
|---|
| 149 |  ;               ORQRATE=Measurement rate to be validated.
 | 
|---|
| 150 |  ;               (req.)
 | 
|---|
| 151 |  ;               ORQUNIT=Unit of measurement for rate, if specified.
 | 
|---|
| 152 |  ;               (opt.)
 | 
|---|
| 153 |  ;   Return value:  1 if rate is valid.
 | 
|---|
| 154 |  ;                  0 if rate is invalid.
 | 
|---|
| 155 |  ;
 | 
|---|
| 156 |  S ORRETURN=$$RATECHK^GMRVPCE0(ORQTYPE,ORQRATE,$G(ORQUNIT))
 | 
|---|
| 157 |  Q
 | 
|---|
| 158 |  ;
 | 
|---|
| 159 | VMTYPES(ORRETURN,ORQTYPE) ;
 | 
|---|
| 160 |  ; This function returns one if ORQTYPE is a valid type abbrev.
 | 
|---|
| 161 |  ; from the PCE Device Interface Specification.
 | 
|---|
| 162 |  S ORRETURN=$$VMTYPES^GMRVPCE0(ORQTYPE)
 | 
|---|
| 163 |  Q
 | 
|---|