| 1 | ACKQHLP ;AUG/JLTP BIR/PTD-QUASAR Help Text ; [ 11/02/95 15:38 ] | 
|---|
| 2 | ;;3.0;QUASAR;;Feb 11, 2000 | 
|---|
| 3 | ;Per VHA Directive 10-93-142, this routine SHOULD NOT be modified. | 
|---|
| 4 | Q:$S('($D(ACKQHLP)#2):1,$E(ACKQHLP)=U:0,$T(@ACKQHLP)="":1,1:0) | 
|---|
| 5 | N ACKTXT,EXP,FIND,I,TAG,X,Y | 
|---|
| 6 | ;  If field 100 display narrative for all word processing fields | 
|---|
| 7 | I $E(ACKQHLP)=U,$P(ACKQHLP,"^",2)="509850.6",$P(ACKQHLP,"^",3)="100" D CPTEXT,DDHLP1 Q | 
|---|
| 8 | I $E(ACKQHLP)=U D DDHLP Q | 
|---|
| 9 | F I=1:1 S TAG=ACKQHLP_"+"_I,@("ACKTXT=$P($T("_TAG_"),"";;"",2)") Q:ACKTXT=""  D PROC W !,ACKTXT | 
|---|
| 10 | K ACKQHLP Q | 
|---|
| 11 | DDHLP ;DISPLAY HELP TEXT FROM DD'S FIELD DESCRIPTION | 
|---|
| 12 | W @IOF | 
|---|
| 13 | DDHLP1 S X(1)=+$P(ACKQHLP,U,2),X(2)=+$P(ACKQHLP,U,3) Q:$S('X(1):1,'X(2):1,'$D(^DD(X(1),X(2),0)):1,1:0) | 
|---|
| 14 | S I=0 F  S I=$O(^DD(X(1),X(2),21,I)) Q:'I  S ACKTXT=^(I,0) D PROC W !,ACKTXT | 
|---|
| 15 | K ACKQHLP Q | 
|---|
| 16 | PROC ; | 
|---|
| 17 | F  Q:ACKTXT'["|"  S EXP=$P(ACKTXT,"|",2) D RESOLV S ACKTXT=$P(ACKTXT,"|")_EXP_$P(ACKTXT,"|",3,245) | 
|---|
| 18 | Q | 
|---|
| 19 | RESOLV ; | 
|---|
| 20 | S X=EXP X ^%ZOSF("UPPERCASE") | 
|---|
| 21 | I Y="TAB" S EXP="",FIND=$F(ACKTXT,"|")-2,$P(EXP," ",FIND\8+1*8-(FIND))="" Q | 
|---|
| 22 | I Y="NOWRAP"!(Y="WRAP") S EXP="" Q  ;NOWRAP IS FORCED NO MATTER | 
|---|
| 23 | I $E(Y,1,4)="S X=" X Y S EXP=X Q | 
|---|
| 24 | Q | 
|---|
| 25 | ; | 
|---|
| 26 | CPTEXT ;  Display C&P exam for Audio # 1305 worksheet narrative | 
|---|
| 27 | W @IOF,?30,"Compensation and Pension Examination" | 
|---|
| 28 | W ! S X="For AUDIO" D CNTR^ACKQUTL(X) | 
|---|
| 29 | W ! S X="#1305 Worksheet" D CNTR^ACKQUTL(X) | 
|---|
| 30 | W !!," An examination of hearing impairment must be conducted by a state-licensed" | 
|---|
| 31 | W !," audiologist and must include a controlled speech discrimination test" | 
|---|
| 32 | W !," (specifically, the Maryland CNC recording) and a pure tone audiometry test in" | 
|---|
| 33 | W !," a sound isolated booth that meets American National Standards Institute" | 
|---|
| 34 | W !," standards (ANSI S3.1.1991) for ambient noise." | 
|---|
| 35 | W !!," Measurements will be reported at the frequencies of 500, 1000, 2000, 3000," | 
|---|
| 36 | W !," and 4000 Hz.  The examination will include the following tests: pure tone" | 
|---|
| 37 | W !," audiometry by air conduction at 250, 500, 1000, 2000, 3000, 4000 Hz, and 8000" | 
|---|
| 38 | W !," Hz; and by bone conduction at 250, 500, 1000, 2000, 3000, and 4000 Hz;" | 
|---|
| 39 | W !," spondee thresholds; speech recognition using the recorded Maryland CNC Test;" | 
|---|
| 40 | W !," tympanometry; and acoustic reflex tests, and, when necessary, Stenger tests." | 
|---|
| 41 | W !," Bone conduction thresholds are measured when the air conduction thresholds" | 
|---|
| 42 | W !," are poorer than 15 dB HL.  A modified Hughson-Westlake procedure will be used" | 
|---|
| 43 | W !," with appropriate masking.  A Stenger test must be administered whenever pure" | 
|---|
| 44 | W !," tone air conduction thresholds at 500, 1000, 2000, 3000, and 4000 Hz" | 
|---|
| 45 | W !," differ by 20 dB or more between the two ears." | 
|---|
| 46 | K DIR S DIR(0)="E",DIR("A")="Press RETURN to continue" W ! D ^DIR | 
|---|
| 47 | ; | 
|---|
| 48 | W @IOF,?30,"Compensation and Pension Examination" | 
|---|
| 49 | W ! S X="For AUDIO" D CNTR^ACKQUTL(X) | 
|---|
| 50 | W ! S X="#1305 Worksheet (Continued)" D CNTR^ACKQUTL(X) | 
|---|
| 51 | W !!," Maximum speech recognition will be reported with the 50-word VA-approved" | 
|---|
| 52 | W !," recording of the Maryland CNC test.  When speech recognition is 92% or less," | 
|---|
| 53 | W !," a performance intensity function will be obtained with a starting" | 
|---|
| 54 | W !," presentation level of 40dB re SRT.  If necessary, the starting level will be" | 
|---|
| 55 | W !," adjusted upward to obtain a level at least 5 dB above the threshold at 2000" | 
|---|
| 56 | W !," Hz.  The examination will be conducted without the use of hearing aids. Both" | 
|---|
| 57 | W !," ears must be examined for hearing impairment even if hearing loss in only one" | 
|---|
| 58 | W !," ear is at issue.",!! | 
|---|
| 59 | ; | 
|---|
| 60 | Q | 
|---|
| 61 | 1 ;; | 
|---|
| 62 | ;; | 
|---|
| 63 | ;;     You are selecting a date range for this report.  Enter a starting | 
|---|
| 64 | ;;     and ending date for which you want the report to run.  The report will | 
|---|
| 65 | ;;     gather all data beginning with (inclusively) the start date and ending | 
|---|
| 66 | ;;     with (inclusively) the ending date. | 
|---|
| 67 | ;; | 
|---|
| 68 | ;;     To run the report for a single day's data, specify that date as | 
|---|
| 69 | ;;     both the beginning and ending date.  Use standard DHCP date format. | 
|---|
| 70 | ;; | 
|---|
| 71 | ;;|S X="" D HELP^%DTC S X=""| | 
|---|
| 72 | 2 ;; | 
|---|
| 73 | ;; | 
|---|
| 74 | ;;     The appointments shown here have already been entered for the | 
|---|
| 75 | ;;     patient/date you have selected.  Answer YES if you wish to edit one | 
|---|
| 76 | ;;     of the appointments shown here.  If you are trying to enter a new | 
|---|
| 77 | ;;     appointment for this patient/date then you should answer NO. | 
|---|
| 78 | ;; | 
|---|
| 79 | 3 ;; | 
|---|
| 80 | ;; | 
|---|
| 81 | ;;     Select the C&P exam you wish to adequate.  You can select by | 
|---|
| 82 | ;;     DATE OF EXAM, by PATIENT NAME, SSN, or initial and last four.  You | 
|---|
| 83 | ;;     can only choose exams with the status AWAITING ADEQUATION. | 
|---|
| 84 | ;; | 
|---|
| 85 | 4 ;; | 
|---|
| 86 | ;; | 
|---|
| 87 | ;;     Subtotals will be shown for clinician(s), other provider(s), or | 
|---|
| 88 | ;;     student(s).  At this time you must decide whether to count the | 
|---|
| 89 | ;;     procedures for a single clinician/other provider/student or to | 
|---|
| 90 | ;;     include all. | 
|---|
| 91 | ;; | 
|---|
| 92 | 6 ;; | 
|---|
| 93 | ;; | 
|---|
| 94 | ;;     Answer YES if you are ready to enter your electronic | 
|---|
| 95 | ;;     signature to release this exam.  Answer NO if this exam is | 
|---|
| 96 | ;;     not ready to be released to the regional office. | 
|---|
| 97 | ;; | 
|---|