source: FOIAVistA/trunk/r/RADIOLOGY_NUCLEAR_MEDICINE-RA/RAO7RO1.m@ 677

Last change on this file since 677 was 628, checked in by George Lilly, 15 years ago

initial load of FOIAVistA 6/30/08 version

File size: 2.1 KB
Line 
1RAO7RO1 ;HISC/FPT-RAD/NM Error Messages ;8/28/97 14:16
2 ;;5.0;Radiology/Nuclear Medicine;**2,75,86**;Mar 16, 1998;Build 7
3 ;
4EN1(RAERR) ; errors encountered with OE v3.0 back & frontdoor transmission
5 S RAEMSG=$P($T(MSG+RAERR),";",4)
6 I RAEMSG]"" Q RAEMSG
7 Q "Error # "_RAERR_" does not exist"
8 ;
9 ;Note: Error code nine (9) disappears with the release of CPRS GUI V27. P86
10 ;
11MSG ; error messages
12 ;;1;Missing/Invalid Order Control
13 ;;2;Missing/Invalid Patient ID
14 ;;3;Missing/Invalid Patient Location
15 ;;4;Missing/Invalid User DUZ
16 ;;5;Missing/Invalid REQUEST URGENCY
17 ;;6;Missing/Invalid REQUESTING PHYSICIAN
18 ;;7;Entered Date/Time is in the Future
19 ;;8;Invalid Procedure, Inactive, no Imaging Type or no Procedure Type
20 ;;9;Patient Class disagrees with Patient Location
21 ;;10;Invalid ISOLATION PROCEDURES
22 ;;11;Invalid MODIFIER(s)
23 ;;12;Missing/Invalid IMAGING LOCATION or not the same as procedure's
24 ;;13;Missing/Invalid MODE OF TRANSPORT
25 ;;14;Missing/Invalid PREGNANT value
26 ;;15;Missing/Invalid CLINICAL HISTORY FOR EXAM
27 ;;16;Missing/Invalid Placer Number
28 ;;17;Missing/Invalid OBX Value Type
29 ;;18;Missing/Invalid CONTRACT/SHARING SOURCE
30 ;;19;Missing/Invalid RESEARCH SOURCE
31 ;;20;Missing/Invalid PRE-OP SCHEDULED DATE/TIME
32 ;;21;Error Filing New Entry
33 ;;22;Missing/Invalid Filler Number
34 ;;23;Missing/Invalid Cancel or Hold Reason
35 ;;24;
36 ;;25;Current status will not permit request to be put in DISCONTINUED status
37 ;;26;Error filing Placer Number
38 ;;27;Missing/Invalid CATEGORY OF EXAM
39 ;;28;Invalid REQUEST DATE (TIME optional)
40 ;;29;CATEGORY OF EXAM cannot be Research AND Contract/Sharing
41 ;;30;Error Filing New Entry in Request Status Times multiple
42 ;;31;Imaging Type mismatch between the Procedure and Imaging Location
43 ;;32;Parent procedure does not have descendents
44 ;;33;Imaging Type mismatch between the Procedure and MODIFIER(s)
45 ;;34;Invalid MODFIERS(s) for a series procedure
46 ;;35;FileMan rejected date/time
47 ;;36;Invalid Approving Rad/Nuc Med physician
48 ;;37;Rad/Nuc Med order not placed in a DISCONTINUED status
49 ;;38;Missing REASON FOR STUDY value
50 ;;39;Invalid REASON FOR STUDY value
Note: See TracBrowser for help on using the repository browser.