source: WorldVistAEHR/trunk/r/AUTOMATED_LAB_INSTRUMENTS-LA/LAJOB1.m@ 1147

Last change on this file since 1147 was 613, checked in by George Lilly, 15 years ago

initial load of WorldVistAEHR

File size: 806 bytes
Line 
1LAJOB1 ;SLC/DCM/RWF - STATUS OF AUTOMATED LAB ROUTINES ;7/11/89 10:29 ;
2 ;;5.2;AUTOMATED LAB INSTRUMENTS;;Sep 27, 1994
3A S U="^" I '$D(IOM) S IOP="HOME" D ^%ZIS
4LA2 S $P(LADASH,"-",IOM)="" W !!!,LADASH,!?30,"LSI INTERFACE STATUS",!,LADASH
5 W !,?5,"LSI",?15,"INST.",?33,"DATA",?42,"DATA",?51,"++ PROGRAM STATUS ++"
6 W !?5,"PORT #",?15,"NAME",?33,"IN LA?",?42,"IN LAH?",?51,"NAME",?62,"ACTIVE",?70,"$J"
7 W !,LADASH
8 F I=0:0 S I=$O(^LAB(62.4,I)) Q:I<1!(I>99) S X=^LAB(62.4,I,0) D LINE
9 W !!
10END K I,J,L,LADASH,Y,X Q
11 Q
12LINE W !?6,I,?15,$E($P(X,U,1),1,15),?34,$S($D(^LA(I,"I")):"Yes",1:"No")
13 S L=$P(X,U,4),Y=0 I L>0 F J=0:0 S J=$O(^LAH(L,1,J)) Q:J<1 I $O(^LAH(L,1,J,1)) S Y=Y+1 Q:Y>5
14 W ?45,$S(Y>2:"Yes",1:"No"),?51,$P(X,U,3),?62,$S($D(^LA("LOCK",I)):"Lock",1:"No"),?70,$S($D(^LA("LOCK",I)):^(I),1:"")
15 Q
Note: See TracBrowser for help on using the repository browser.