source: WorldVistAEHR/trunk/r/AUTOMATED_LAB_INSTRUMENTS-LA/LASMA2.m@ 691

Last change on this file since 691 was 613, checked in by George Lilly, 15 years ago

initial load of WorldVistAEHR

File size: 1.5 KB
Line 
1LASMA2 ;SLC/RWF - SMA II/(GENERATION 2) SYSTEM ROUTINE ;7/20/90 10:08 ;
2 ;;5.2;AUTOMATED LAB INSTRUMENTS;;Sep 27, 1994
3 ;CROSS LINK BY ID (patient no.) or IDE (lab no.) /use with FORMAT OPTION 4B.
4LA1 S:$D(ZTQUEUED) ZTREQ="@" S LANM=$T(+0),TSK=$O(^LAB(62.4,"C",LANM,0)) Q:TSK<1
5 Q:'$D(^LA(TSK,"I",0))
6 K LATOP D ^LASET Q:'TSK S X="TRAP^"_LANM,@^%ZOSF("TRAP")
7LA2 K TV S TOUT=0,A=1 D IN G QUIT:TOUT,LA2:$E(IN,3)'="/" D QC
8 S TOUT=0,BAD=0 F A=2:1:10 D IN,QC G QUIT:TOUT
9 S V=$E(Y(3),6,15) D NUM S RMK=V,DIL=0 S:RMK["DIL" DIL=+RMK
10 F A=4,6,8 F IX=2:11:67 S X=$E(Y(A),IX,IX+10),I=+X,V=$P(X,"=",2) D NUM I "B*+"'[$E(V,$L(V)) S:DIL V=V*DIL S @TC(I,1)=+V ;V check for error flags
11 S V=$E(Y(2),1,9),TRAY=+$E(Y(1),16,17),CUP=+$E(Y(1),19,20) D NUM S ID=+V,V=$E(Y(3),1,5) D NUM S IDE=+V
12LA3 X LAGEN
13 F I=0:0 S I=$O(TV(I)) Q:I<1 S:TV(I,1)]"" ^LAH(LWL,1,ISQN,I)=TV(I,1)
14 I $D(RMK),$L(RMK) D RMK^LASET
15 G LA2
16QC ;QC TESTING HERE; S BAD=1 IF DONT STORE
17 I A=2,$L(Y(1))<21 S Y(1)=Y(1)_IN,A=1 Q ;EXT sent at 21 for File search.
18 I A<4,$E(IN,4)="=" S Y(A)="",A=A+1 G QC ;Controls don't sent pat. no.
19 S Y(A)=IN Q
20NUM S X="" F JJ=1:1:$L(V) S:$A(V,JJ)>32 X=X_$E(V,JJ)
21 S V=X Q
22IN S CNT=^LA(TSK,"I",0)+1 IF '$D(^(CNT)) S TOUT=TOUT+1 Q:TOUT>9 H 5 G IN
23 S ^LA(TSK,"I",0)=CNT,IN=^(CNT),TOUT=0
24 S:IN["~" CTRL=$P(IN,"~",2),IN=$P(IN,"~",1)
25 Q
26 Q
27OUT S CNT=^LA(TSK,"O")+1,^("O")=CNT,^("O",CNT)=OUT
28 LOCK ^LA("Q") S Q=^LA("Q")+1,^("Q")=Q,^("Q",Q)=TSK LOCK
29 Q
30QUIT LOCK ^LA(TSK) H 1 K ^LA(TSK),^LA("LOCK",TSK),^TMP($J),^TMP("LA",$J)
31 Q
32TRAP D ^LABERR S T=TSK D SET^LAB G @("LA2^"_LANM) ;ERROR TRAP