[623] | 1 | ENEQ4 ;WIRMFO/SAB-PURGE EQUIPMENT INV FILE ;2.25.97
|
---|
| 2 | ;;7.0;ENGINEERING;**40**;Aug 17, 1993
|
---|
| 3 | ;
|
---|
| 4 | DEL ;Delete Equipment Record entry
|
---|
| 5 | S ENEDNX=$D(^XUSEC("ENEDNX",DUZ))
|
---|
| 6 | W !!,"This option completely deletes a specific equipment record. If"
|
---|
| 7 | W !,"you would rather move equipment records to an archive media, then"
|
---|
| 8 | W !,"exit this option and use the Engineering Archive Module instead."
|
---|
| 9 | DELSEQ ; select equipment record for deletion
|
---|
| 10 | W !
|
---|
| 11 | D GETEQ^ENUTL G:Y'>0 DELX
|
---|
| 12 | S ENDA=+Y
|
---|
| 13 | F ENI=0,1,2,3 S ENY(ENI)=$G(^ENG(6914,ENDA,ENI))
|
---|
| 14 | ;
|
---|
| 15 | ; display equipment data
|
---|
| 16 | W @IOF
|
---|
| 17 | W !,"ENTRY #: ",ENDA
|
---|
| 18 | W !!,?2,"MFGR EQUIP NAME: ",$P(ENY(0),U,2)
|
---|
| 19 | W !,?2,"EQUIP CATEGORY: ",$$GET1^DIQ(6914,ENDA,6)
|
---|
| 20 | W !,?2,"CSN: ",$$GET1^DIQ(6914,ENDA,18)
|
---|
| 21 | S ENX=$$GET1^DIQ(6914,ENDA,"18:2") I ENX]"" W " (",ENX,")"
|
---|
| 22 | W !!,?2,"MANUFACTURER: ",$$GET1^DIQ(6914,ENDA,1)
|
---|
| 23 | W !,?2,"MODEL: ",$P(ENY(1),U,2),?42,"SERIAL #: ",$P(ENY(1),U,3)
|
---|
| 24 | W !!,?2,"CMR: ",$$GET1^DIQ(6914,ENDA,19)
|
---|
| 25 | W ?42,"USE STATUS: ",$$GET1^DIQ(6914,ENDA,20)
|
---|
| 26 | W !,?2,"ACQUISITION DATE: ",$$FMTE^XLFDT($P(ENY(2),U,4))
|
---|
| 27 | W ?34,"LE: ",$P(ENY(2),U,6)
|
---|
| 28 | W ?42,"DISPOSITION DATE: ",$$FMTE^XLFDT($P(ENY(3),U,11)),!
|
---|
| 29 | ;
|
---|
| 30 | ; validate selection
|
---|
| 31 | K ENV
|
---|
| 32 | S ENX=$$CHKFA^ENFAUTL(ENDA)
|
---|
| 33 | I +ENX S ENV(1)="It is currently reported to Fixed Assets in Austin."
|
---|
| 34 | E I $P(ENX,U,2)]"" S ENV(2)="It was previously reported to Fixed Assets in Austin."
|
---|
| 35 | I $P(ENY(0),U,4)="NX",'ENEDNX S ENV(3)="Security key ENEDNX is required to delete NX equipment."
|
---|
| 36 | I $P(ENY(3),U,1)=1 S ENV(4)="USE STATUS is IN USE."
|
---|
| 37 | I $P(ENY(3),U,11)="" S ENV(5)="DISPOSITION DATE is blank."
|
---|
| 38 | I $D(ENV) D G DELSEQ
|
---|
| 39 | . W $C(7),!,"This equipment entry can not be deleted because:"
|
---|
| 40 | . S ENI=0 F S ENI=$O(ENV(ENI)) Q:'ENI W !,?2,ENV(ENI)
|
---|
| 41 | ;
|
---|
| 42 | ; confirm deletion
|
---|
| 43 | S DIR(0)="Y",DIR("A")="Delete this entry"
|
---|
| 44 | D ^DIR K DIR G:$D(DIRUT) DELX I 'Y G DELSEQ
|
---|
| 45 | ;
|
---|
| 46 | ; first close any open work orders
|
---|
| 47 | S ENTXT(1)="Automatically closed when equipment record was deleted."
|
---|
| 48 | S DA=0 F S DA=$O(^ENG(6920,"G",ENDA,DA)) Q:'DA I $P($G(^ENG(6920,DA,5)),U,2)="" D
|
---|
| 49 | . D WP^DIE(6920,DA_",",40,"A","ENTXT")
|
---|
| 50 | . S DIE="^ENG(6920,",DR="36///T;32///^S X=""COMPLETED"""
|
---|
| 51 | . D ^DIE
|
---|
| 52 | K DIE,DR,ENTXT
|
---|
| 53 | ; then delete equipment
|
---|
| 54 | S DIK="^ENG(6914,",DA=ENDA D ^DIK K DIK
|
---|
| 55 | W !,"Equipment entry # ",ENDA," was deleted."
|
---|
| 56 | ;
|
---|
| 57 | G DELSEQ
|
---|
| 58 | ;
|
---|
| 59 | DELX ; delete equipment record exit
|
---|
| 60 | K DA,DIC,DIE,DIK,DIROUT,DIRUT,DR,DTOUT,DUOUT,X,Y
|
---|
| 61 | K END,ENDA,ENEDNX,ENI,ENV,ENWO,ENX,ENY
|
---|
| 62 | Q
|
---|
| 63 | ;
|
---|
| 64 | ;ENEQ4
|
---|