[613] | 1 | ENLBL10 ;(WASH ISC)/DH-Print Bar Coded Equipment Labels ;10.10.97
|
---|
| 2 | ;;7.0;ENGINEERING;**12,35,45**;Aug 17, 1993
|
---|
| 3 | PM ;Range of PM numbers
|
---|
| 4 | S ENERR=0 D STA^ENLBL3 G:ENEQSTA="^" QUIT^ENLBL3
|
---|
| 5 | N DIC,DIE,DA,DR,X,X1,X2,I,J,K,I1
|
---|
| 6 | PM1 S X="" R !,"Starting with: ",X:DTIME G:X=""!($E(X)="^") EXIT1^ENLBL8
|
---|
| 7 | I $E(X)="?" D G PM1
|
---|
| 8 | . W !!,"Property Management (PM) numbers should consist of four numbers, followed",!,"by a dash (-), followed by four more numbers. There may be an alphabetic"
|
---|
| 9 | . W !,"at the end (for a grand total of ten characters), but there usually isn't."
|
---|
| 10 | . W !!,"The first four numbers correspond to the Federal Supply Classification Code."
|
---|
| 11 | . W !,"The next four numbers are assigned at the site, usually by the Property",!,"Management Section in A&MM."
|
---|
| 12 | . W !!,"It is the intent of VACO Program Offices to phase out PM numbers in favor of",!,"the AEMS/MERS entry number, but no official timetable has been established.",!
|
---|
| 13 | S FR=X I FR'?4N1"-"4N W !,"Doesn't look like a standard PM number. Are you sure",*7 S %=2 D YN^DICN G:%<0 EXIT1^ENLBL8 G:%=2 PM1 I %=0 W !,"PM #'s look like '7025-5001'." G PM1
|
---|
| 14 | I FR=+FR S FR=FR_" "
|
---|
| 15 | PM2 S X="" R !,"and ending with: ",X:DTIME G:X="^"!(X="") EXIT1^ENLBL8 S TO=X I FR]TO W !!,"Your ending point does not follow your starting point. I'm confused.",*7 G PM1
|
---|
| 16 | I TO'?4N1"-"4N W !,"Are you sure" S %=2 D YN^DICN G:%<0 EXIT1^ENLBL8 G:%=2 PM2 I %=0 W !,"PM numbers look like '7025-5001'." G PM2
|
---|
| 17 | I '$D(^ENG(6914,"C",FR)) S I=$O(^ENG(6914,"C",FR)) I I]TO W !!,*7,"Sorry, but there doesn't appear to be any equipment in specified range." G PM1
|
---|
| 18 | D EN^ENLBL9 I $D(DIRUT) G EXIT1^ENLBL8
|
---|
| 19 | I '$D(ENEQIO),%<0 G EXIT1^ENLBL8
|
---|
| 20 | S ENLOCSRT=1
|
---|
| 21 | PM21 W !,"Sort labels by LOCATION" S %=1 D YN^DICN G:%<0 EXIT1^ENLBL8 I %=0 W !,"Say YES to sort labels by DIVISION, BUILDING, then by ROOM.",!,"If you say NO, labels will be sorted by VA PM #." G PM21
|
---|
| 22 | S:%=2 ENLOCSRT=0
|
---|
| 23 | S %ZIS("A")="Select BAR CODE PRINTER: ",%ZIS("B")="",%ZIS="Q" I $D(ENEQIO),ENEQIO=IO S %ZIS=""
|
---|
| 24 | K IO("Q") D ^%ZIS K %ZIS G:POP EXIT1^ENLBL8
|
---|
| 25 | S ENBCIO=IO,ENBCIOSL=IOSL,ENBCIOF=IOF,ENBCION=ION,ENBCIOST=IOST,ENBCIOST(0)=IOST(0),ENBCIOS=IOS S:$D(IO("S")) ENBCIO("S")=IO("S")
|
---|
| 26 | I $D(IO("Q")) K IO("Q") S ZTIO=ION,ZTRTN="PM3^ENLBL10",ZTSAVE("D*")="",ZTSAVE("EN*")="",ZTSAVE("FR")="",ZTSAVE("TO")="",ZTDESC="NX Barcode Labels by PM #" D ^%ZTLOAD K ZTSK G EXIT1^ENLBL8
|
---|
| 27 | PM3 S ENEQBY="PM # "_FR_" thru "_TO
|
---|
| 28 | I $D(ENEQIO) D OPEN^ENLBL9 I POP G:$D(ZTQUEUED) REQ^ENLBL8 W !,*7,"Companion Printer UNAVAILABLE." D HOLD G EXIT1^ENLBL8
|
---|
| 29 | K ^TMP($J) S I1=FR I $D(^ENG(6914,"C",FR)) S DA=$O(^ENG(6914,"C",FR,0)) D STATCK^ENLBL3 I DA]"" D:ENLOCSRT SORT^ENLBL3 I 'ENLOCSRT D PMNSRT
|
---|
| 30 | F K=0:0 S I1=$O(^ENG(6914,"C",I1)) Q:I1=""!(I1]TO) S DA=$O(^ENG(6914,"C",I1,0)) D STATCK^ENLBL3 I DA]"" D:ENLOCSRT SORT^ENLBL3 D:'(DA#10) DOTS^ENLBL3 I 'ENLOCSRT D PMNSRT
|
---|
| 31 | I $D(^TMP($J)) U ENBCIO D FORMAT^ENLBL7 S I1="" F J1=0:0 S I1=$O(^TMP($J,I1)) Q:I1="" F DA=0:0 S DA=$O(^TMP($J,I1,DA)) Q:DA'>0 U ENBCIO D NXPRT^ENLBL7 D:$D(ENEQIO) CPRNT^ENLBL9 D:'(DA#10) DOTS^ENLBL3 D BCDT^ENLBL7
|
---|
| 32 | G EXIT^ENLBL8
|
---|
| 33 | ;
|
---|
| 34 | PMNSRT S ^TMP($J,I1,DA)="" Q
|
---|
| 35 | HOLD W !,"Press <RETURN> to continue..." R X:DTIME
|
---|
| 36 | Q
|
---|
| 37 | ;ENLBL10
|
---|