[613] | 1 | ENSA1 ;(WASH ISC)/DH-MedTester Interface ;12/21/2000
|
---|
| 2 | ;;7.0;ENGINEERING;**9,14,21,45,48,54,67**;Aug 17, 1993
|
---|
| 3 | UPLD ;Read from ESU
|
---|
| 4 | K ^ENG("TMP",ENTID)
|
---|
| 5 | W !!,"Enter the device to which the MedTester is connected.",! D ^%ZIS Q:POP
|
---|
| 6 | S ENCTEON=^%ZOSF("EON"),ENCTEOFF=^%ZOSF("EOFF"),ENCTTYPE=^%ZOSF("TYPE-AHEAD"),ENCTOPEN=$G(^%ZIS(2,IOST(0),10)),ENCTCLOS=$G(^%ZIS(2,IOST(0),11))
|
---|
| 7 | U IO D OFF W !,"...OK, use the MedTester 'PALL' function to send the data. Please",!,"be sure that you are connected to a MedTester COMM port and that the",!,"MedTester PRINTER port is OFF."
|
---|
| 8 | D ON R X:60 I '$T D OFF W !!,"Data transmission failure.",*7 D HOLD G EXIT
|
---|
| 9 | S X=$TR(X,$C(0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31)) ;strip control chars
|
---|
| 10 | ; next 4 lines will cause routine to ignore blank lines (Open-M) problem
|
---|
| 11 | F Q:$E(X)'=" " S X=$E(X,2,245)
|
---|
| 12 | S I=0 I X]"" S I=I+1,^ENG("TMP",ENTID,I)=X
|
---|
| 13 | F R X:10 Q:'$T I X]"" S X=$TR(X,$C(10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27)) D I X]"" S I=I+1,^ENG("TMP",ENTID,I)=X D:'(I#5) MARK
|
---|
| 14 | . F Q:$E(X)'=" " S X=$E(X,2,245)
|
---|
| 15 | R %:1 ;clear buffer
|
---|
| 16 | D OFF
|
---|
| 17 | D ^%ZISC
|
---|
| 18 | Q ;Data upload finished
|
---|
| 19 | ;
|
---|
| 20 | MARK I IO=IO(0) D OFF
|
---|
| 21 | U IO(0) W "." U IO
|
---|
| 22 | I IO=IO(0) D ON
|
---|
| 23 | Q
|
---|
| 24 | ;
|
---|
| 25 | ON X ENCTOPEN U IO X ENCTEOFF,ENCTTYPE
|
---|
| 26 | Q
|
---|
| 27 | ;
|
---|
| 28 | OFF X ENCTCLOS,ENCTEON U IO(0)
|
---|
| 29 | Q
|
---|
| 30 | ;
|
---|
| 31 | PROCS ;Process test results
|
---|
| 32 | K ^TMP($J)
|
---|
| 33 | N PMTOT S ENBRANCH="RECNUM^DATE^OPCODE^DEVICE^COMNTS^OTHER"
|
---|
| 34 | S (ENREC,ENEQ,ENLOC,ENEMP,ENTEC,ENSTDT,ENSN,ENMOD,ENWP,ENTIME,ENTEST)="",(ENFAIL,ENFLG,ENPG,ENY)=0 K ENLBL
|
---|
| 35 | READ S ENSA1=0 F S ENSA1=$O(^ENG("TMP",ENTID,ENSA1)) Q:'ENSA1 D MEDCHK
|
---|
| 36 | I $D(ENLBL) D UPDT
|
---|
| 37 | I $D(PMTOT) D ^ENBCPM8
|
---|
| 38 | Q ;Return control to ENSA
|
---|
| 39 | ;
|
---|
| 40 | MEDCHK S X=^ENG("TMP",ENTID,ENSA1) F Q:$E(X)'=$C(32) S X=$E(X,2,245)
|
---|
| 41 | I X["MedTester" S X="MedTester REC #"_$P(X," REC #",2)
|
---|
| 42 | S ENX=X,X1=$S($E(X,1,9)="MedTester":1,$E(X,1,9)="SEQUENCE:":2,$E(X,1,14)="OPERATOR CODE:":3,$E(X,1,8)="OP CODE:":3,$E(X,1,18)="DEVICE INFORMATION":4,$E(X,1,9)="COMMENTS:":5,1:6)
|
---|
| 43 | D @($P(ENBRANCH,U,X1))
|
---|
| 44 | Q
|
---|
| 45 | ;
|
---|
| 46 | RECNUM D:$D(ENLBL) UPDT K ENLBL ; post data (if any) from last test
|
---|
| 47 | ; init variables for this test
|
---|
| 48 | K ENSN,ENMOD,ENPMN,ENSTDT,ENPMWO(0)
|
---|
| 49 | S (ENEQ,ENLOC,ENEMP,ENTEC,ENSTDT,ENSN,ENMOD,ENWP,ENTIME,ENTEST)="",(ENFAIL,ENFLG)=0
|
---|
| 50 | S X=$TR($P(ENX,"REC #",2),$C(32))
|
---|
| 51 | S ENREC=X D:ENPAPER LNPRNT^ENSA7
|
---|
| 52 | Q
|
---|
| 53 | DATE ;Date of ESA
|
---|
| 54 | N DELYR ; for Y2K
|
---|
| 55 | S X=^ENG("TMP",ENTID,ENSA1),X=$P(X,"DATE:",2),X1=$P(X,"TIME:",1)
|
---|
| 56 | S X1=$TR(X1,$C(10,32))
|
---|
| 57 | S XM=$P(X1,"/",1),XD=$P(X1,"/",2),XY=$P(X1,"/",3)
|
---|
| 58 | S:$L(XM)<2 XM="0"_XM
|
---|
| 59 | S:$L(XD)<2 XD="0"_XD
|
---|
| 60 | S:$L(XY)<2 XY="0"_XY ; added by *67 for non-y2k compliant Medtesters
|
---|
| 61 | S DELYR=$E(DT,2,3)-XY
|
---|
| 62 | S ENSTDT=$E(DT)+$S(DELYR>79:1,DELYR<-20:-1,1:0)_XY_XM_XD
|
---|
| 63 | I ENSTDT'?7N S ENSTDT="" ; result was an invalid date format
|
---|
| 64 | K XM,XD,XY
|
---|
| 65 | I ENPAPER D LNPRNT^ENSA7
|
---|
| 66 | Q
|
---|
| 67 | OPCODE ;Operator
|
---|
| 68 | S (ENTEC,ENEMP)="",X=$TR($P(X,":",2),$C(32))
|
---|
| 69 | I X]"" D
|
---|
| 70 | . I X=+X S ENTEC=X,ENEMP=$S($D(^ENG("EMP",X,0)):$P(^(0),U),1:"") Q
|
---|
| 71 | . I $D(^ENG("EMP","B",X)) S ENEMP=X,ENTEC=$O(^(X,0)) Q
|
---|
| 72 | . S X(1)=$L(X),X(2)=$O(^ENG("EMP","B",X)) I $E(X(2),1,X(1))=X D
|
---|
| 73 | .. I $E($O(^ENG("EMP","B",X(2))),1,X(1))=X Q
|
---|
| 74 | .. S ENTEC=$O(^ENG("EMP","B",X(2),0)),ENEMP=$P(^ENG("EMP",ENTEC,0),U)
|
---|
| 75 | D:ENPAPER LNPRNT^ENSA7
|
---|
| 76 | Q
|
---|
| 77 | DEVICE ;Equipment id
|
---|
| 78 | F J=1,2 S ENSA1=$O(^ENG("TMP",ENTID,ENSA1)),X(J)=^ENG("TMP",ENTID,ENSA1)
|
---|
| 79 | S X(3)="",X=$G(^ENG("TMP",ENTID,ENSA1+1)) F Q:$E(X)'=" " S X=$E(X,2,30)
|
---|
| 80 | I $E(X,1,7)="CONTROL" D ; accomodate MedTester 5000C
|
---|
| 81 | . S ENSA1=ENSA1+1,X(3)=$TR($P(X,":",2),$C(10)) F Q:$E(X(3))'=" " S X(3)=$E(X(3),2,50)
|
---|
| 82 | . S I=$L(X(3)) F Q:$E(X(3),I)'=" "!(I<1) S I=I-1,X(3)=$E(X(3),1,I)
|
---|
| 83 | S X=$P(X(1),"LOC:",2) F J=0:0 Q:$E(X)'=" " S X=$E(X,2,30)
|
---|
| 84 | S ENLOC=X I $E(ENLOC,1,2)="SP" S ENLOC=$E(ENLOC,3,30)
|
---|
| 85 | I ENLOC[" " S ENLOC=$P(ENLOC," ")
|
---|
| 86 | S X=$L(ENLOC) I $E(ENLOC,X)=" " S ENLOC=$E(ENLOC,1,(X-1))
|
---|
| 87 | S X=$P(X(2),":",2)
|
---|
| 88 | S X=$S($E(X,$L(X)-1,$L(X))="SN":$E(X,1,$L(X)-2),$E(X,$L(X)-7,$L(X))="SERIAL #":$E(X,1,$L(X)-8),1:X)
|
---|
| 89 | S X=$TR(X,$C(32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47))
|
---|
| 90 | S ENMOD(0)=$E(X,1,16)
|
---|
| 91 | S X=$P(X(2),":",3)
|
---|
| 92 | S X=$S($E(X,$L(X)-1,$L(X))="CN":$E(X,1,$L(X)-2),$E(X,$L(X)-8,$L(X))="CONTROL #":$E(X,1,$L(X)-9),1:X)
|
---|
| 93 | S X=$TR(X,$C(10,32))
|
---|
| 94 | S ENSN(0)=$E(X,1,16)
|
---|
| 95 | I X(3)]"" S X=X(3)
|
---|
| 96 | E D
|
---|
| 97 | . S X=$TR($P(X(2),":",4),$C(10)) F Q:$E(X)'=" " S X=$E(X,2,30)
|
---|
| 98 | . S I=$L(X) F Q:$E(X,I)'=" "!(I<1) S I=I-1,X=$E(X,1,I)
|
---|
| 99 | S ENLBL=X,ENEQ="" D DEVICE^ENSA7
|
---|
| 100 | K X Q
|
---|
| 101 | COMNTS ;MedTester comments
|
---|
| 102 | S X=$TR($E(X,11,128),$C(10))
|
---|
| 103 | S ENWP=X_" MedTester" S:$E(X)="#" ENFAIL=1
|
---|
| 104 | I ENPAPER D LNPRNT^ENSA7
|
---|
| 105 | Q
|
---|
| 106 | OTHER ;All other, mainly specific test results
|
---|
| 107 | I $E(X,1,10)="USER TIME:" S ENTIME=+$TR($P(X,":",2)," ")
|
---|
| 108 | ;
|
---|
| 109 | ; distinguish between EKG and DEFIB tests and hope that we're not
|
---|
| 110 | ; missing other flavors of MedTester procedures
|
---|
| 111 | ;
|
---|
| 112 | ; if line has text indicating start of a test results section then
|
---|
| 113 | ; set ENFLG = 1 (true) so subsequent lines will be checked for
|
---|
| 114 | ; presence of '#' which indicates a test failure
|
---|
| 115 | ;
|
---|
| 116 | I $E(X,1,12)="LINE VOLTAGE" S ENFLG=1,ENTEST="EKG" ; for esa test
|
---|
| 117 | I $E(X,1,5)="DEFIB" S ENFLG=1,ENTEST="DEFIB" ; for defib test
|
---|
| 118 | ;
|
---|
| 119 | ; if line has text indicating section after test results then
|
---|
| 120 | ; set ENFLG = 0 (false) so subsequent lines will not be checked for
|
---|
| 121 | ; presence of '#'
|
---|
| 122 | ;
|
---|
| 123 | I $E(X,1,11)="PERFORMANCE" S ENFLG=0 ; for any test
|
---|
| 124 | ;
|
---|
| 125 | ; if ENFLG true then check for failure unless line starts STEP#
|
---|
| 126 | ; since defib tests use 'STEP #' as a column header
|
---|
| 127 | ;
|
---|
| 128 | I ENFLG,$E(X,1,4)'="STEP",X["#" S ENFAIL=1
|
---|
| 129 | ;
|
---|
| 130 | I ENPAPER D LNPRNT^ENSA7
|
---|
| 131 | Q
|
---|
| 132 | ;
|
---|
| 133 | UPDT ;Update Equipment File
|
---|
| 134 | S ENEQ(0)=1 I ENEQ]"" D UPDATE^ENSA2 D:$D(^ENG(6914,ENEQ,0)) POST^ENSA4
|
---|
| 135 | I ENEQ(0),ENLBL?4N1"-"4N0.1A D PMN^ENSA2 I ENEQ]"",$D(^ENG(6914,ENEQ,0)) D POST^ENSA4
|
---|
| 136 | I ENEQ(0) D NOLBL^ENSA3
|
---|
| 137 | I $D(ENXP("?")) D DEVCK3^ENSA7 K ENXP("?")
|
---|
| 138 | Q
|
---|
| 139 | ;
|
---|
| 140 | HOLD W !,"Press <RETURN> to continue..." R X:DTIME
|
---|
| 141 | Q
|
---|
| 142 | EXIT G EXIT^ENSA3
|
---|
| 143 | ;ENSA1
|
---|