| 1 | ECDSSCRN ;BIR/RHK - Enter Event Code Screens ;30 Mar 95
 | 
|---|
| 2 |  ;;2.0; EVENT CAPTURE ;;8 May 96
 | 
|---|
| 3 |  ;Routine for entering event code screens
 | 
|---|
| 4 | START ; Check for location
 | 
|---|
| 5 |  W @IOF
 | 
|---|
| 6 |  I $O(^DIC(4,"LOC",""))="" W !,"You have no locations flagged for event cature.",!! Q
 | 
|---|
| 7 | UNIT ; Select unit
 | 
|---|
| 8 |  K DIC S ECNOPE="",DIC=724,DIC(0)="QEAMZ",DIC("A")="Select DSS Unit: ",DIC("S")="I $P(^(0),U,8)" D ^DIC K DIC G:Y<0 END
 | 
|---|
| 9 |  S ECU=+Y,ECUN=$P(Y,U,2) D CHECK
 | 
|---|
| 10 |  I $D(DUOUT)!($D(DTOUT)) G END
 | 
|---|
| 11 |  I ECNOPE G UNIT
 | 
|---|
| 12 | CAT ; Check if unit uses categories
 | 
|---|
| 13 |  I $P(^ECD(ECU,0),U,11) D  S ECUDIR=$S($D(DUOUT):"END",$D(ECUERR):"UNIT",1:"PROC") W @IOF G @ECUDIR
 | 
|---|
| 14 |  .S DIC=726
 | 
|---|
| 15 |  .S DIC(0)="AEQMZ"
 | 
|---|
| 16 |  .S DIC("S")="I '$P(^(0),U,3)!($P(^(0),U,3)>DT)"
 | 
|---|
| 17 |  .S DIC("A")="Select Category: "
 | 
|---|
| 18 |  .D ^DIC K DIC Q:$D(DUOUT)
 | 
|---|
| 19 |  .I Y<0 S ECUERR=1 Q
 | 
|---|
| 20 |  .S ECUCAT=+Y
 | 
|---|
| 21 | PROC ; Set procedures
 | 
|---|
| 22 |  ; Find highest entry number
 | 
|---|
| 23 |  F ECUP=0:0 S ECUP=$O(^ECD(ECU,"PRO",ECUP)) Q:+$O(^(ECUP))'>0
 | 
|---|
| 24 |  S ECUP=ECUP+1
 | 
|---|
| 25 |  I '$D(ECUCAT) S ECUCAT=""
 | 
|---|
| 26 |  S DIR(0)="724.011,.01",DIR("A")="Select Procedure" D ^DIR K DIR
 | 
|---|
| 27 |  I +Y'>0 G END
 | 
|---|
| 28 |  S ECUPRO=Y
 | 
|---|
| 29 |  I $D(^ECD(ECU,"PRO","CB",ECUCAT,ECUPRO)) D  G PROC
 | 
|---|
| 30 |  .W !,"That procedure already exists.",!!
 | 
|---|
| 31 |  .S ECUPROP=$O(^ECD(ECU,"PRO","CB",ECUCAT,ECUPRO,""))
 | 
|---|
| 32 |  .I $P(^ECD(ECU,"PRO",ECUPROP,0),U,3),($P(^(0),U,3)<DT) D
 | 
|---|
| 33 |  ..S Y=$P(^ECD(ECU,"PRO",ECUPROP,0),U,3) X ^DD("DD")
 | 
|---|
| 34 |  ..W "This procedure was inactivated on ",Y,".  You may use the 'Inactivate",!,"Event Code Screen option to change this date.",!!
 | 
|---|
| 35 |  .K ECUP
 | 
|---|
| 36 |  S ^ECD(ECU,"PRO",ECUP,0)=Y_"^"_ECUCAT
 | 
|---|
| 37 |  I '$D(^ECD(ECU,"PRO",0)) S ^ECD(ECU,"PRO",0)="^724.011AV^^"
 | 
|---|
| 38 |  ; Set the cross references for this entry
 | 
|---|
| 39 |  S ^ECD(ECU,"PRO","B",Y,ECUP)=""
 | 
|---|
| 40 |  S ^ECD(ECU,"PRO","C",ECUCAT,ECUP)=""
 | 
|---|
| 41 |  K DA,ECUP,Y,X G PROC
 | 
|---|
| 42 | STOP ; Stop loop and check for another category
 | 
|---|
| 43 |  G CAT
 | 
|---|
| 44 | END ;
 | 
|---|
| 45 |  K DA,DIE,DIK,DR,ECNOPE,ECU,ECUCAT,ECUDIR,ECUERR,ECUN,ECUP,ECUPRO,ECUPROP,X,Y
 | 
|---|
| 46 |  Q
 | 
|---|
| 47 | CHECK ; Check to see if active unit
 | 
|---|
| 48 |  I $P(^ECD(ECU,0),U,6) S ECNOPE=1
 | 
|---|
| 49 |  I ECNOPE W !!,"This DSS Unit has not been activated for use in Event",!,"Capture software.",!! S DIR(0)="E" D ^DIR K DIR
 | 
|---|
| 50 |  Q
 | 
|---|