[613] | 1 | GMVDCCNV ;HOIFO/DAD,FT-VITALS COMPONENT: CONVERT UNITS ;9/29/00 09:15
|
---|
| 2 | ;;5.0;GEN. MED. REC. - VITALS;;Oct 31, 2002
|
---|
| 3 | ;
|
---|
| 4 | ; This routine uses the following IAs:
|
---|
| 5 | ; #10143 - XLFMSMT calls (supported)
|
---|
| 6 | ;
|
---|
| 7 | CNV(GMVALUE,GMVMSYS,GMVOPER,GMVTYPE) ;
|
---|
| 8 | ; Unit conversion
|
---|
| 9 | ; Input:
|
---|
| 10 | ; GMVALUE = The value to be converted
|
---|
| 11 | ; GMVMSYS = The desired Measurement system
|
---|
| 12 | ; GMVOPER = The operation taking place (G - Get data, S - Save data)
|
---|
| 13 | ; GMVTYPE = The Vital Type abbreviation
|
---|
| 14 | ; Output:
|
---|
| 15 | ; The measurement expressed in the desired units
|
---|
| 16 | I $G(GMVALUE)]"",$G(GMVMSYS)]"",$G(GMVOPER)]"",$G(GMVTYPE)]"" D
|
---|
| 17 | . I "^T^"[(U_GMVTYPE_U) S GMVALUE=$$TMP(GMVALUE,GMVMSYS,GMVOPER)
|
---|
| 18 | . I "^WT^"[(U_GMVTYPE_U) S GMVALUE=$$WEI(GMVALUE,GMVMSYS,GMVOPER)
|
---|
| 19 | . I "^CVP^"[(U_GMVTYPE_U) S GMVALUE=$$CVP(GMVALUE,GMVMSYS,GMVOPER)
|
---|
| 20 | . I "^HT^AG^FH^HC^CG^"[(U_GMVTYPE_U) S GMVALUE=$$LEN(GMVALUE,GMVMSYS,GMVOPER)
|
---|
| 21 | . Q
|
---|
| 22 | Q $G(GMVALUE)
|
---|
| 23 | ;
|
---|
| 24 | TMP(GMVALUE,GMVMSYS,GMVOPER) ;
|
---|
| 25 | ; Temperature conversion
|
---|
| 26 | ; Input:
|
---|
| 27 | ; GMVALUE = The value to be converted
|
---|
| 28 | ; GMVMSYS = The desired Measurement system
|
---|
| 29 | ; GMVOPER = The operation taking place (G - Get data, S - Save data)
|
---|
| 30 | ; Output:
|
---|
| 31 | ; The measurement expressed in the desired units
|
---|
| 32 | I GMVMSYS="M" D
|
---|
| 33 | . N GMVFR,GMVTO
|
---|
| 34 | . I GMVOPER="G" S GMVFR="F",GMVTO="C"
|
---|
| 35 | . I GMVOPER="S" S GMVFR="C",GMVTO="F"
|
---|
| 36 | . S GMVALUE=$P($$TEMP^XLFMSMT(GMVALUE,GMVFR,GMVTO)," ")
|
---|
| 37 | . Q
|
---|
| 38 | Q GMVALUE
|
---|
| 39 | ;
|
---|
| 40 | LEN(GMVALUE,GMVMSYS,GMVOPER) ;
|
---|
| 41 | ; Length conversion
|
---|
| 42 | ; Input:
|
---|
| 43 | ; GMVALUE = The value to be converted
|
---|
| 44 | ; GMVMSYS = The desired Measurement system
|
---|
| 45 | ; GMVOPER = The operation taking place (G - Get data, S - Save data)
|
---|
| 46 | ; Output:
|
---|
| 47 | ; The measurement expressed in the desired units
|
---|
| 48 | I GMVMSYS="M" D
|
---|
| 49 | . N GMVFR,GMVTO
|
---|
| 50 | . I GMVOPER="G" S GMVFR="IN",GMVTO="CM"
|
---|
| 51 | . I GMVOPER="S" S GMVFR="CM",GMVTO="IN"
|
---|
| 52 | . S GMVALUE=$P($$LENGTH^XLFMSMT(GMVALUE,GMVFR,GMVTO)," ")
|
---|
| 53 | . Q
|
---|
| 54 | Q GMVALUE
|
---|
| 55 | ;
|
---|
| 56 | WEI(GMVALUE,GMVMSYS,GMVOPER) ;
|
---|
| 57 | ; Weight conversion
|
---|
| 58 | ; Input:
|
---|
| 59 | ; GMVALUE = The value to be converted
|
---|
| 60 | ; GMVMSYS = The desired Measurement system
|
---|
| 61 | ; GMVOPER = The operation taking place (G - Get data, S - Save data)
|
---|
| 62 | ; Output:
|
---|
| 63 | ; The measurement expressed in the desired units
|
---|
| 64 | I GMVMSYS="M" D
|
---|
| 65 | . N GMVFR,GMVTO
|
---|
| 66 | . I GMVOPER="G" S GMVFR="LB",GMVTO="KG"
|
---|
| 67 | . I GMVOPER="S" S GMVFR="KG",GMVTO="LB"
|
---|
| 68 | . S GMVALUE=$P($$WEIGHT^XLFMSMT(GMVALUE,GMVFR,GMVTO)," ")
|
---|
| 69 | . Q
|
---|
| 70 | Q GMVALUE
|
---|
| 71 | ;
|
---|
| 72 | CVP(GMVALUE,GMVMSYS,GMVOPER) ;
|
---|
| 73 | ; Central Venous Pressure conversion
|
---|
| 74 | ; Input:
|
---|
| 75 | ; GMVALUE = The value to be converted
|
---|
| 76 | ; GMVMSYS = The desired Measurement system
|
---|
| 77 | ; GMVOPER = The operation taking place (G - Get data, S - Save data)
|
---|
| 78 | ; Output:
|
---|
| 79 | ; The measurement expressed in the desired units
|
---|
| 80 | I GMVMSYS="M" D
|
---|
| 81 | . I GMVOPER="G" S GMVALUE=$J(GMVALUE/1.36,0,3)
|
---|
| 82 | . I GMVOPER="S" S GMVALUE=$J(GMVALUE*1.36,0,3)
|
---|
| 83 | . Q
|
---|
| 84 | Q GMVALUE
|
---|