source: WorldVistAEHR/trunk/r/GEN_MED_OTHER-GMV/GMVDCHLP.m@ 949

Last change on this file since 949 was 613, checked in by George Lilly, 15 years ago

initial load of WorldVistAEHR

File size: 4.5 KB
Line 
1GMVDCHLP ;HOIFO/DAD,FT-VITALS COMPONENT: HELP TEXT ;9/29/00 09:17
2 ;;5.0;GEN. MED. REC. - VITALS;;Oct 31, 2002
3 ;
4 ; This routine uses the following IAs:
5 ; #10104 - ^XLFSTR calls (supported)
6 ;
7HELP(RESULT,GMVITTYP) ;
8 ; *** Get help text ***
9 ; Input:
10 ; GMVITTYP = A vital type abbreviation
11 ; Output:
12 ; RESULT() = The help text
13 N GMVLINE,GMVTXT K RESULT
14 S GMVITTYP=$$UP^XLFSTR(GMVITTYP)
15 I $T(@GMVITTYP)]"" D
16 . F GMVLINE=1:1 S GMVTXT=$P($T(@GMVITTYP+GMVLINE),";;",2) Q:GMVTXT=U D
17 .. S RESULT(GMVLINE)=GMVTXT
18 .. Q
19 . Q
20 Q
21 ;;
22AG ;;ABDOMINAL GIRTH
23 ;;Abdominal girth must be numeric with no decimal places
24 ;;Must be in the range 0 - 150 IN (0 - 381 CM).
25 ;;^
26AUD ;;AUDIOMETRY
27 ;;Audiometry is entered as eight readings for right ear followed by
28 ;;eight readings for left ear. Readings are delimited by slashes (/).
29 ;;Must be in the range 0 - 110.
30 ;;E.g.:
31 ;; 100/100/100/95/90/90/85/80/105/105/105/105/100/100/95/90/
32 ;;^
33BP ;;BLOOD PRESSURE
34 ;;Blood Pressure must be in the range 0 - 300 and in one of the
35 ;;following formats:
36 ;;E.g.:
37 ;; 120/80 (systolic / diastolic)
38 ;; 120/100/80 (systolic / mean / diastolic)
39 ;; 120 (systolic [must have doppler or palpated qualifier])
40 ;;^
41CG ;;CIRCUMFERENCE/GIRTH
42 ;;Circumference/girth must be numeric with a maximum of two decimal
43 ;;places. Must be in the range 0 - 200 IN (0 - 508 CM).
44 ;;^
45CVP ;;CENTRAL VENOUS PRESSURE
46 ;;Central venous pressure must be numeric with a maximum of one decimal
47 ;;place. Must be in the range -13.6 - 136 CM H2O (-10 - 100 mmHg).
48 ;;^
49FH ;;FUNDAL HEIGHT
50 ;;Fundal height must be numeric with no decimal places.
51 ;;Must be in the range 10 - 50 IN (25 - 127 CM).
52 ;;^
53FT ;;FETAL HEART TONES
54 ;;Fetal heart tones must be numeric with no decimal places.
55 ;;Must be in the range 50 - 250.
56 ;;^
57HC ;;HEAD CIRCUMFERENCE
58 ;;Head circumference if entered in inches must be in the range of
59 ;;10 - 30 inches with a maximum of three decimal places, where the
60 ;;decimal part must be a multiple of 0.125.
61 ;;E.g.:
62 ;; 23, 24.125, 23.25, 30.375, 28.5
63 ;;Head circumfrence if entered in centimeters must be in the range of
64 ;;26 - 76 centimeters with a maximum of two decimal places.
65 ;;E.g.:
66 ;; 30.2, 45
67 ;;^
68HE ;;HEARING
69 ;;Hearing is entered as N for Normal, or A for Abnormal.
70 ;;^
71HT ;;HEIGHT
72 ;;Height must be numeric with a maximum of two decimal places.
73 ;;Must be in the range 1 - 100 IN (2.54 - 254 CM).
74 ;;^
75P ;;PULSE
76 ;;Pulse must be numeric between 0 and 300 with no decimal places.
77 ;;^
78PN ;;PAIN
79 ;;Pain score is entered as one of the following integers.
80 ;; 0 = Patient verbalizes no pain.
81 ;; 1 to 10 = Patient verbalizes having pain.
82 ;; ( 1 = slightly uncomfortable/minimal pain)
83 ;; (10 = worst imaginable pain)
84 ;; 99 = Patient unable to respond/communicate pain level.
85 ;;^
86PO2 ;;PULSE OXIMETRY
87 ;;Pulse oximetry must be numeric with no decimal places.
88 ;;The value is interpreted as a percentage (0 - 100 %).
89 ;;Supplemental O2 information may also be entered:
90 ;;O2 Flow rate must be numeric with a maximum of one decimal place.
91 ;;Must be in the range 0.5 - 20 liters / minute.
92 ;;O2 concentration must be numeric with no decimal places.
93 ;;The value is interpreted as a percentage (0 - 100 %).
94 ;;^
95R ;;RESPIRATION
96 ;;Respiration must be numeric between 0 and 99 with no decimal places.
97 ;;^
98T ;;TEMPERATURE
99 ;;Temperature must be numeric with a maximum of two decimal places.
100 ;;Must be in the range 45 - 120 F (7.2 - 48.9 C).
101 ;;^
102TON ;;TONOMETRY
103 ;;Tonometry is entered a reading for right eye, followed by a slash
104 ;;(/) followed by a reading for the left eye. The slash is required.
105 ;;Must be in the range 0 - 80.
106 ;;E.g.:
107 ;; 18/18, /20, 18/, 10/13
108 ;;^
109VC ;;VISION CORRECTED
110 ;;Vision corrected must entered in the form RightEye/LeftEye. Only
111 ;;denominators should be entered, the initial 20/ is assumed. Must
112 ;;be in the range 10 - 999.
113 ;;E.g.:
114 ;; 20/20 (Right eye 20/20. Left eye 20/20.)
115 ;; 20/ (Right eye 20/20. No left eye measurement.)
116 ;; /20 (No right eye measurement. Left eye 20/20.)
117 ;;^
118VU ;;VISION UNCORRECTED
119 ;;Vision uncorrected must entered in the form RightEye/LeftEye. Only
120 ;;denominators should be entered, the initial 20/ is assumed. Must
121 ;;be in the range 10 - 999.
122 ;;E.g.:
123 ;; 20/20 (Right eye 20/20. Left eye 20/20.)
124 ;; 20/ (Right eye 20/20. No left eye measurement.)
125 ;; /20 (No right eye measurement. Left eye 20/20.)
126 ;;^
127WT ;;WEIGHT
128 ;;Weight must be numeric with a maximum of two decimal places.
129 ;;Must be in the range 0 - 1500 LB (0 - 681 KG).
130 ;;^
Note: See TracBrowser for help on using the repository browser.