[613] | 1 | PRCSRIE ;WISC/SAW/DXH - BUILD AND MAINTAIN REPETITIVE ITEM LIST FILE ;7.26.99
|
---|
| 2 | V ;;5.1;IFCAP;**13,53**;Oct 20, 2000
|
---|
| 3 | ;Per VHA Directive 10-93-142, this routine should not be modified.
|
---|
| 4 | ;ENTER REP ITEM
|
---|
| 5 | N CC S CC=0
|
---|
| 6 | D ENF^PRCSUT(1) G W5^PRCSUT3:'$D(PRC("SITE")) G EXIT:Y<0
|
---|
| 7 | ;I $$ISSUPFCP^PRCSCK(PRC("SITE"),+PRC("CP")) S CC=+$$SUPPLYCC^PRCSCK()
|
---|
| 8 | ;I $$VALIDCC^PRCSECP(PRC("SITE"),+PRC("CP"),CC) S DIC("B")=CC G GOTDFLT
|
---|
| 9 | S CC=$$GETCCCNT^PRCSECP(PRC("SITE"),+PRC("CP"))
|
---|
| 10 | I 'CC G CC ;GO BAIL OUT IF NO CC'S DEFINED
|
---|
| 11 | I +CC=1 S DIC("B")=$P(CC,U,2)
|
---|
| 12 | GOTDFLT S DIC("A")="Select COST CENTER: "
|
---|
| 13 | S DIC="^PRC(420,PRC(""SITE""),1,+PRC(""CP""),2,",DIC(0)="AEMNQZ"
|
---|
| 14 | D ^DIC I Y'>0 G EXIT
|
---|
| 15 | S Y=$P(Y(0),"^") I '$D(^PRCD(420.1,Y,0)) G ERREXIT
|
---|
| 16 | ;
|
---|
| 17 | STF N REP
|
---|
| 18 | S REP=1
|
---|
| 19 | S X=PRC("SITE")_"-"_PRC("FY")_"-"_PRC("QTR")_"-"_$P(PRC("CP")," ")_"-"_Y
|
---|
| 20 | D EN1^PRCSUT3
|
---|
| 21 | S DLAYGO=410.3,DIC="^PRCS(410.3,",DIC(0)="LZ" D ^DIC K DLAYGO
|
---|
| 22 | G W4^PRCSUT3:Y<0 S (PRCSDA,DA)=+Y
|
---|
| 23 | L +^PRCS(410.3,DA):15 G:$T=0 PRCSRIE
|
---|
| 24 | Q:$D(PRCHSPD)
|
---|
| 25 | D NOW^%DTC S $P(^PRCS(410.3,DA,0),"^",2)=0,$P(^(0),"^",4)=%
|
---|
| 26 | S PRCSNO=$P(^PRCS(410.3,DA,0),"^") S:$D(PRCSIP) $P(^(0),"^",3)=PRCSIP
|
---|
| 27 | S DIC(0)="AEMQ",DIE=DIC,DR="[PRCSRI]",DIE("NO^")=1 D ^DIE
|
---|
| 28 | S DA=PRCSDA L -^PRCS(410.3,DA) K DIE("NO^")
|
---|
| 29 | D CALC^PRCSRIE1
|
---|
| 30 | W1 W !!,"Would you like to create another repetitive item list entry"
|
---|
| 31 | S %=2 D YN^DICN
|
---|
| 32 | G W1:%=0,EXIT:%=2!(%<0)
|
---|
| 33 | W !! K PRCSV,PRCSV1
|
---|
| 34 | G PRCSRIE
|
---|
| 35 | ;
|
---|
| 36 | VENDOR ;INPUT TRANS VENDOR FIELD-410.3
|
---|
| 37 | Q:'$D(PRC("SITE")) Q:'$D(PRC("CP")) S Z0=$P(^PRCS(410.3,DA(1),1,DA,0),"^") K:'Z0 X G EX1:'Z0,EX1:'$D(^PRC(441,Z0,2,0))
|
---|
| 38 | I $D(^PRC(420,PRC("SITE"),1,+PRC("CP"),0)),$P(^(0),"^",12)=2 S DIC("S")="I '$D(^PRC(440,""AC"",""S"",+Y))"
|
---|
| 39 | S DIC="^PRC(441,Z0,2,",DIC(0)="QEMNZ" D ^DIC K DIC("S") I Y'>0 K X G EX1
|
---|
| 40 | I '$D(^PRC(440,+Y,0)) K X G EX1
|
---|
| 41 | S X=$P(^PRC(440,+Y,0),"^"),$P(^PRCS(410.3,DA(1),1,DA,0),"^",5)=+Y
|
---|
| 42 | VENDOR1 S Z=$P(Y(0),"^",2) I Z="" D VENDOR2 Q
|
---|
| 43 | I Z=0 W !,"NOTE: This item has a unit cost of $0.00" ;HEH-0502-40043
|
---|
| 44 | S $P(^PRCS(410.3,DA(1),1,DA,0),"^",4)=Z
|
---|
| 45 | EX I $P(Y(0),"^",12) W $C(7),!,"NOTE: This item has a minimum order quantity of ",$P(Y(0),"^",12)
|
---|
| 46 | I $P(Y(0),"^",11) W $C(7),!,"NOTE: This item must be ordered in multiples of ",$P(Y(0),"^",11)
|
---|
| 47 | I $P(Y(0),"^",8) S Z(1)=$P(Y(0),"^",7),Z(1)=$S($D(^PRCD(420.5,+Z(1),0)):$P(^(0),"^",2),1:"") I Z(1)'="" W $C(7),!,"NOTE: This item has a packaging multiple/unit of purchase of ",$P(Y(0),"^",8)_"/"_Z(1)
|
---|
| 48 | EX1 K DIC,Z0,Z("DR")
|
---|
| 49 | Q
|
---|
| 50 | ;
|
---|
| 51 | VENDOR2 K DIC,Z0,Z("DR")
|
---|
| 52 | S NOCOST=1
|
---|
| 53 | S DIC(0)="AEMQ",DIC="^PRCS(410.3,",DIK=DIC_DA(1)_",1,"
|
---|
| 54 | ;
|
---|
| 55 | W !!," The vendor you have chosen has no unit cost for this item."
|
---|
| 56 | W !," Please do one of the following:"
|
---|
| 57 | W !," 1. Choose another item."
|
---|
| 58 | W !," 2. Choose another vendor."
|
---|
| 59 | W !," 3. Contact A&MM to enter the unit cost.",!!
|
---|
| 60 | ;
|
---|
| 61 | QUIT
|
---|
| 62 | ;
|
---|
| 63 | VENDORC ;CK MND SOURCE/PREF VENDOR
|
---|
| 64 | S Z0=$P(^PRCS(410.3,DA(1),1,DA,0),"^") K PRCSV1 I 'Z0 K Z0 Q
|
---|
| 65 | I $D(^PRC(420,PRC("SITE"),1,+PRC("CP"),0)),$P(^(0),"^",12)=2 G V2
|
---|
| 66 | S Z2=$P(^PRCS(410.3,DA(1),1,DA,0),"^",3),Z3="This item has a mandatory source (vendor) of "
|
---|
| 67 | I $P(^PRC(441,Z0,0),"^",8) S Y=$P(^(0),"^",8) I $D(^PRC(440,Y,0)) S X=$P(^(0),"^") Q:X=Z2
|
---|
| 68 | I W !,$C(7),Z3,X S $P(^PRCS(410.3,DA(1),1,DA,0),"^",3)=X,$P(^(0),"^",5)=Y,^PRCS(410.3,DA(1),1,"AC",X,DA)="",PRCSV=1 I Z2'="" K ^PRCS(410.3,DA(1),1,"AC",Z2,DA)
|
---|
| 69 | K Z2,Z3 I $D(PRCSV) S Y(0)=$S($D(^PRC(441,Z0,2,Y,0)):^(0),1:"") G VENDOR1
|
---|
| 70 | V2 S X=0,X=$O(^PRC(441,Z0,4,"B",PRC("SITE")_$P(PRC("CP")," "),X)) I X,$D(^PRC(441,Z0,4,X,0)),$P(^(0),"^",3)'="" S PRCSV1=$P(^(0),"^",3)
|
---|
| 71 | I $D(PRCSV1),$D(^PRC(440,PRCSV1,0)) S PRCSV1=$P(^(0),"^") W !,$C(7),"The following is the preferred (but not mandatory) vendor for this item." K X,Z0
|
---|
| 72 | Q
|
---|
| 73 | CC W $C(7),!!,"There are no cost centers entered for this station and control point in the Fund",!,"Control Point file. You must enter one or more cost centers before continuing." R !,"Press return to continue: ",X:5
|
---|
| 74 | EXIT K %,DA,DIC,DIE,DR,PRCSDA,PRCSL,PRCSNO,PRCSV,PRCSV1,Y(0),X,Y,Z,Z0,Z1 Q
|
---|
| 75 | ERREXIT W $C(7),!!,"That Cost Center is invalid."
|
---|
| 76 | R " Press return to continue: ",X:5
|
---|
| 77 | G EXIT
|
---|