1 | LR7OU64 ;SLC/DCM/FHS/DALISC - RESULT CODE NLT LINKING UTILITY AUTO ; 12/3/1997
|
---|
2 | ;;5.2;LAB SERVICE;**153,201**;Sep 27, 1994
|
---|
3 | EN ;
|
---|
4 | ;Find matches between file 64 and 60
|
---|
5 | D MSG
|
---|
6 | LIST ;
|
---|
7 | K DIR S DIR("A")="Would you like a list of RESULT NLT CODES from LABORATORY TEST file",DIR(0)="Y",DIR("B")="No"
|
---|
8 | D ^DIR G:$D(DIRUT)!($D(DTOUT))!($D(DUOUT)) END I Y=1 D G:$D(DIRUT)!($D(DTOUT))!($D(DUOUT))!(Y=0) END G LK
|
---|
9 | . D LST K DIR S DIR("A")="Ready to start linkage procedure ",DIR(0)="Y"
|
---|
10 | . D ^DIR
|
---|
11 | W ! K DIR S DIR("A")="Ready to proceed",DIR(0)="Y"
|
---|
12 | D ^DIR G:$D(DTOUT)!($D(DUOUT))!($D(DIROUT))!(Y'=1) END
|
---|
13 | LK W !!,$$CJ^XLFSTR("Do you want to automatically link entries when there is an exact match",80)
|
---|
14 | W !,$$CJ^XLFSTR("on the NAME in both files",80) S %=2 D YN^DICN G:%=-1 END
|
---|
15 | I %=0 W !!,$$CJ^XLFSTR("Answer YES to automatically link the entries, or NO to be prompted for each",80) G LK
|
---|
16 | S AUTO=$S(%=1:1,1:0)
|
---|
17 | LAB ;
|
---|
18 | W:$G(AUTO) !?5,"Press Return to Stop Auto Update",!
|
---|
19 | S (END,LRN)="" F S LRN=$O(^LAB(60,"B",LRN)) Q:LRN=""!($G(END)) D
|
---|
20 | . S LRIEN="" F S LRIEN=+$O(^LAB(60,"B",LRN,LRIEN)) Q:LRIEN<1!($G(END)) I '$G(^(LRIEN)) D CHECK
|
---|
21 | W:'$G(END) !!,$$CJ^XLFSTR("End of loop",80),!
|
---|
22 | G END
|
---|
23 | Q
|
---|
24 | CHECK ;
|
---|
25 | S LRMIEN=0
|
---|
26 | Q:'$D(^LAB(60,LRIEN,0))#2!('$P(^(0),";",2))!($P($G(^LAB(60,LRIEN,64)),U,2))!($G(END))
|
---|
27 | S LRDATA=$P(^LAB(60,LRIEN,0),U),LRTY=$P(^(0),U,3) Q:LRTY=""!(LRTY="N")
|
---|
28 | S LRNU=$$UP^XLFSTR(LRN),X=+$O(^LAM("D",LRNU,0)) I $D(^LAM(X,0)),^(0)'["~" S LRMIEN=X
|
---|
29 | D:'LRMIEN 64 Q:'LRMIEN!($G(END))
|
---|
30 | Q:'$D(^LAM(LRMIEN,0))#2 S LRCODE=$P(^(0),U,2) Q:'LRCODE!($D(^LAB(60,"AE",LRCODE)))
|
---|
31 | Q:'$D(^LAM(LRMIEN,0)) S LRMNAME=$P(^(0),U)
|
---|
32 | W !!,"60 = ",LRDATA,!,"64 = ",LRMNAME_" "_LRCODE
|
---|
33 | D LINK(LRIEN,LRMIEN,AUTO)
|
---|
34 | Q
|
---|
35 | 64 ;Look for NATIONAL VA LAB CODE
|
---|
36 | S LRMIEN=0,I=+$P($G(^LAB(60,LRIEN,64)),U,2) I $D(^LAM(I,0)),^(0)'["~" S LRMIEN=I
|
---|
37 | Q:'LRMIEN
|
---|
38 | W !,$C(7),?5,"Did not find a exact name match for Lab Test "_LRDATA,!
|
---|
39 | K DIR
|
---|
40 | W !," Want to use the ["_$P(^LAM(LRMIEN,0),U)_"] NATIONAL VA LAB CODE instead?"
|
---|
41 | K DIR S DIR(0)="Y" D ^DIR S:Y'=1 LRMIEN=0 Q
|
---|
42 | Q
|
---|
43 | LINK(X60,X641,DOIT) ;Link the 2 files
|
---|
44 | S LRDATA="`"_X60 I DOIT S %=1 G L2
|
---|
45 | L1 W !?5,"Link the two entries" S %=2 D YN^DICN Q:%=2 I %=-1 S END=1 Q
|
---|
46 | I $G(DTOUT) S END=1 Q
|
---|
47 | I %=0 W !,"Enter Yes to link the entries, No to leave it alone." G L1
|
---|
48 | L2 K DIE,DA,DR,DIC S DIE="^LAB(60,",DA=X60,DR="64.1///`"_X641,DLAYGO=60 D ^DIE K DLAYGO
|
---|
49 | I $P($G(^LAB(60,X60,64)),U,2) W !?32,"o----LINKED----o",! D Q
|
---|
50 | . R X:1 I $T W !?20,"User terminated update",!,$C(7) S END=1
|
---|
51 | W !!?15,"***************** NOT LINKED ***************",!
|
---|
52 | W !!?5,"Press Return to continue" R X:DTIME S:$G(DTOUT)!($E(X)=U) END=1
|
---|
53 | Q
|
---|
54 | END ;
|
---|
55 | Q:$G(LRDBUG)
|
---|
56 | K %,AUTO,DA,DIC,DIE,DIR,DOIT,DR,END,LRDATA,LRIEN,LRMIEN,LRN,LRNU
|
---|
57 | K LRSUF,LRTY,X,X60,X64,Y,LRMNAME,D1,D0,DLAYGO,I,LRCODE,END
|
---|
58 | K FLG,XXX,ZZ,ZZ1,X,Y,Y64,DLAYGO,DX,S
|
---|
59 | Q
|
---|
60 | LST ;
|
---|
61 | K ^TMP("LR",$J),DIC I $O(^LAB(60,"AE",0))="" W !,"Nothing in X-Ref to Print.",!! Q
|
---|
62 | W !!,$$CJ^XLFSTR("I will produce a list of ",80)
|
---|
63 | W !,$$CJ^XLFSTR("NATIONAL VA Code / Result NLT codes from LABORATORY TEST file",80),!
|
---|
64 | K %ZIS S %ZIS="QN",%ZIS("A")="Printer Name " D ^%ZIS G:POP CLEAN
|
---|
65 | I IO'=IO(0)!($D(IO("Q"))) S ZTRTN="DQ^LR7OU64",ZTIO=ION,ZTDESC="PRINT NLT CODES FROM ^LAB(60 " W !!?10,"Report Queued to "_ION,! D ^%ZTLOAD,^%ZISC G CLEAN
|
---|
66 | DQ K ^TMP("LR",$J),DX S:$D(ZTQUEUED) ZTREQ="@"
|
---|
67 | W !!,$$CJ^XLFSTR("List of NATIONAL VA Code / Result NLT codes from LABORATORY TEST file",80),!!
|
---|
68 | W ?6,$$NOW^XLFDT,!
|
---|
69 | S LRNLT="" F S LRNLT=$O(^LAB(60,"AE",LRNLT)) Q:LRNLT="" D
|
---|
70 | . S LRLAB=0 F S LRLAB=$O(^LAB(60,"AE",LRNLT,LRLAB)) Q:LRLAB<1 D
|
---|
71 | . . S ^TMP("LR",$J,$P(^LAB(60,LRLAB,0),U),LRNLT)=LRLAB
|
---|
72 | S DIC="^LAB(60,"
|
---|
73 | S NODE="^TMP(""LR"","_$J_")" F S NODE=$Q(@NODE) Q:$QS(NODE,2)'=$J D
|
---|
74 | . S DA=@NODE,DR=64 W !,"Test Name: ",$P(^LAB(60,DA,0),U)
|
---|
75 | . D EN^LRDIQ S:$E(IOST,1,2)="P-" S=0
|
---|
76 | CLEAN K DIC,DA,NODE,LRNLT,LRLAB,DR,DX,S,^TMP("LR",$J)
|
---|
77 | Q
|
---|
78 | MSG W !,$$CJ^XLFSTR("This option will Auto Link NLT RESULT CODE to Laboratory test file (#60).",80)
|
---|
79 | W !,$$CJ^XLFSTR("NLT RESULT CODE is used by the LEDI software to identify",80)
|
---|
80 | W !,$$CJ^XLFSTR("test results returned by Host Laboratories.",80)
|
---|
81 | W !,$$CJ^XLFSTR("ONLY GENERIC NLT CODES CAN BE LINKED TO LAB TEST ",80),!!
|
---|
82 | W !,$$CJ^XLFSTR("Only ATOMIC lab tests can have an NLT RESUTL CODE.",80),!
|
---|
83 | Q
|
---|