English French Notes Complete/Exclude NTE|2 NTE|3 NTE|4 DOD CMOP Safety BHS,MSH,ORC,RXE,ZR1,PID,BTS Order Sequence RX Number Batch Orders Batch Totals DOD Facility PSXDODNT- DOD CMOP PROCESS ERROR CAPTURE DOD CMOP INTERFACE STOPPED IRREGULARLY The DOD CMOP Interface has been idle more than 20 minutes The XTMP audit trail has been stored in ^XTMP( If this message is appearing frequently contact your CMOP IRM support DOD PSXDODNT LOGGER Processing Files: Nxtfile3a PSXNTSTOP-1 nxtfile4 Finish of DOD CMOP Error on File DOD CMOP encountered the following error. Please investigate File: The file has been moved into the Hold directory zter2:Error Finish & Removal of PLEASE INVESTIGATE - CMOP/DOD error disable PSXDODNT auto error trapping PSX DOD CMOP INTERFACE CMOP DOD QUERY Can't link order # from 552.4 to 552.2 Routine PSXDODQY NTE|8 FHS|^~\&|VISTA| BHS|^~\&|VISTA| RXD| ZR2| FTS| Error occurred at KIL+4^PSXDODQY There isn't an automatic job queued to run under this option. Auto Transmissions are already scheduled. Current schedule began : Number of days to transmit thru: Next transmission scheduled for: Rescheduling Frequency : Do you want to unschedule automatic processing This job is currently running, wait until the task has finished before stopping the job. The CMOP System file is in use, try later. Job Unscheduled. This task does not exist. CMOP Auto-Transmission Terminated Cancellation of Auto-Transmission Schedule. Facility : Initiating Official: Date Cancelled : CMOP CS Auto-Transmission Terminated Cancellation of CS Auto-Transmission Schedule. There are no duplicate Rx's in the file! CMOP Duplicate Rx Report Duplicate Rx Report Query # Orig Qry Orig Completed Time QRD| NTE|99 Delete these Rx's Yes - deletes the duplicate Rx's from the CMOP Release file. No - Will not delete the duplicate Rx's from the CMOP Release file. The Query Interface is stopped!! The Query Interface is already running!! Do you want to Stop the Query The Query interface is running. Answer Yes to stop it. Do you want to Start the Query The Query interface is stopped. Answer Yes to start it. CMOP Query JOB QUEUED This prescription cannot be edited during CMOP processing. (No editing) QTY ( Drug is being edited by another process, try again later... DO YOU WANT TO MARK THIS DRUG AS A Enter `Y' to mark this drug as a or `N' to unmark as a Consolidated Mail Outpatient Pharmacy system. CMOP Error Encountered Transmission of Batch Data Re-Transmission of Batch Data Purge of CMOP RX QUEUE file Filing of CMOP Dispense Data Background Auto-transmission of Data Release Data Data Validation Date/Time : Process : Error Type : Description : Action Taken: Recommended action: The following data is missing in the OUTPATIENT SITE file (#59). No data transmission will occur without this information. Correct invalid data. Invalid or missing data The retransmitted batch will be placed in a hold status. Please release the correct batch when ready. The retransmitted batch was not downloaded into the files. Call IRM to check data and correct Missing Data - No match found for return data. Return data not filed for Rx listed, background release not performed. Invalid data During processing of Vendor return data, CMOP attempted to release the following Rx. This Rx has already been Released locally!. This will invalidate your stock levels for this drug! Rx was not released by CMOP. RX# RX # Fill Data Field SSN NAME Rx's not sent to CMOP but still suspended for transmission. can't be retransmitted again. Contact the IRM for help. RETRANSMISSION ERROR has been retransmitted once. There is either a system problem or there is a problem with the data in the batch. Please contact your local IRM for assistance in determining and correcting the problem. Once the problem has been corrected the IRM can reset the batch and allow you to retransmit. Consolidated Mail Outpatient Pharmacy Install for Host Facility. You must be a valid user and DUZ(0) must be set to the Outpatient Pharmacy Version 6.0 (or greater) not found. This version is required to continue CMOP installation. Kernel Version 8.0 (or greater) not found. This version is required to continue CMOP installation. National Drug File Version 3.16 (or greater) not found. This version is required to continue CMOP installation. Nothing Downloaded *****Release Data Acknowledgements > 24 hours OUTSTANDING***** *****Rejected Orders OUTSTANDING***** CMOP SYSTEM STATUS Transmissions Queued Orders/Rx's: Nothing in the Queue Last Order Processed Last Query Completed Background Process Last Ran Scheduled For Release Data Filed in Master Database..... Not Scheduled Database Purge............................ Release File Purge........................ Release Acknowledgement File Purge........ Query Request Interval: This is the minimum time interval between query requests. Enter the number in hour(s) and/or fractions of an hour interval. Example: 1.25 = 12 hr 25 min, .30 = 30 min, 1 = 1 hr. Query Limit Request: This is the maximum number of Rx's that will be accepted during a query request. Enter a numeric value between 1 and 99999. Days to Retain Release Summary: This is the number of days of Release Acknowledgements that will be retained in the file system. Maximum number of days is 10, minimum number of days is 0. Enter a number value between 1 and 10. Maximum number of days to keep is 10. Minimum number of days to keep is 1. CMOP DRUG Cost Missing You must first use Kernel Option Scheduling to setup the option 'PSX DOD CMOP INTERFACE'. Host Directory Paths Next Run Archive Edit Paths

or Schedule , or Exit JOB1 Unexpected character ( ) has been received ( while Idling. Check INTERFACE connection. JOB2 Stop interface request detected from DHCP. JOB0 STARTING THE INTERFACE Print Facility-Batch #: is currently being printed. Please select another batch or No data to for CMOP Msg # . Select another batch. Select Label Printer: You must choose a printer or OK TO ASSUME LABEL ALIGNMENT IS CORRECT ? Enter Y if labels are OK, N if they need to be aligned. PRINTER IS BUSY. ALIGN LABELS SO THAT A PERFORATION IS AT THE TOP OF THE PRINT HEAD AND THE LEFT SIDE IS AT COLUMN ZERO. PRESS RETURN WHEN READY: IS THIS CORRECT ? CMOP Host Label Print LABELS Queued to Print!! Labels may NOT be printed while the CMOP Background Filer Interface Please try again later... Mfg ________ Lot# ________ Days Supply: Signature__________________________________ ZMP| *Print Name:_________________________________* Routing: MAIL Last fill: Pat. St <--------Label Boundaries-----------------------><----------Vertical Perforation----------------><----------Vertical Perforation bottom of form \/ mailed to you at a future date. Rx# Drug copies back to us. Apply enough postage CMOP LABEL RESTART UTILITY To run the Label Restart Utility you will need the Rx number of the last USEABLE Rx that printed, as well as the CMOP Order # where the error occurred. Did the error occur during Reprint If the error occurred while reprinting labels answer YES, otherwise press enter. Enter Beginning CMOP Order #: This is a required response. Enter Enter Ending CMOP Order #: Ending order # MUST FOLLOW beginning order #. Try again. Enter the last USABLE Rx number printed or 'RETURN' to start at the first Rx in order NO MATCHING RX NUMBER FOUND...Searching There is only one Rx in this order. To print it, press RETURN at the prompt. You have chosen the last Rx in this order. If you want to print this Rx, enter the Rx preceding this Rx within the order or press RETURN to print the entire order. You selected CMOP order # If this is correct, please choose the last USABLE Rx that printed from the following list: BATCH REPRINTED by Please try again,later. No Device Selected CMOP Data Transmission Report Job Canceled Data Transmission # Facility : Received on Total Orders: Total Rx's: RX NUMBER Select Facility Batch Reference # : TRANSMITTED : RECEIVED : TO VENDOR : RX # : REC'D FROM VENDOR : REFILL # DRUG ID : QTY : COST : RX STATUS : CANCELLATION REASON : BY EMPLOYEE : PROCESSED DT/TM : QUERY ID # RELEASE TYPE: REMOTE ERROR CONDITION: Release date already exists. Rx entry missing. Fill mismatch. Transmission number mismatch. No CMOP event multiple. Fill does not exist LOT # : EXP DATE : PACKAGE ID DATE SHIPPED: CMOP Return Message Timer CMOP Acknowledgement not Received An acknowledgment message for transmission # has not been received within the specified time. Please contact the CMOP facility to see if there is a problem. Schedule CS Auto Transmission Unschedule Auto-Transmission Schedule, Cancel Auto Transmission Schedule. Facility : Initiating Official : Cancellation Date : Begin Automatic Transmissions : Scheduling Frequency (hours) : Current date Removed from CMOP Suspense - Mail Status Change CMOP Not Dispensed Rx List, Not Dispensed Rx Report for the The following prescriptions were not dispensed by the vendor: Transmitted under CMOP ID: Note: Local Drug File entry is no longer MARKED for CMOP Instructions: Prescriptions cannot be processed at CMOP for the reason listed above. Please review the prescription and take the appropriate action(s). If you have any questions, contact your CMOP contact person. CMOP Release Return Problems has already been marked as processed Auto-Transmission Schedule NONE - Canceled Auto-transmission Schedule. Date Initiated : MST1 ENQ received with no terminator while Bidding for Master status. MST2 NAK received with no terminator while Bidding for Master status. MST3 ACK without 0 received while Bidding for Master status. MST4 Garbage received while Bidding for Master status. MST5 NAK received while Bidding for Master status. MST6 No response from CMOP while Bidding for Master status. MST7 Simultaneous bid for Master status by CMOP and DHCP. MST8 ACK received with no terminator while Bidding for Master status. MST9 CMOP won't respond, waiting 45 seconds to try again RX Resuspended for CMOP Disaster Recovery until RX Resuspended for CMOP #################### #################### #################### #################### #################### #################### #################### #################### #################### #################### #################### #################### #################### #################### ####################