MAGGTU41 ;WOIFO/GEK - Version Control utilities  ; [ 06/20/2001 08:57 ]
 ;;3.0;IMAGING;**46**;16-February-2007;;Build 1023
 ;; Per VHA Directive 2004-038, this routine should not be modified.
 ;; +---------------------------------------------------------------+
 ;; | Property of the US Government.                                |
 ;; | No permission to copy or redistribute this software is given. |
 ;; | Use of unreleased versions of this software requires the user |
 ;; | to execute a written test agreement with the VistA Imaging    |
 ;; | Development Office of the Department of Veterans Affairs,     |
 ;; | telephone (301) 734-0100.                                     |
 ;; | The Food and Drug Administration classifies this software as  |
 ;; | a medical device.  As such, it may not be changed in any way. |
 ;; | Modifications to this software may result in an adulterated   |
 ;; | medical device under 21CFR820, the use of which is considered |
 ;; | to be a violation of US Federal Statutes.                     |
 ;; +---------------------------------------------------------------+
 ;;
 Q
NOTOKB(X) ; Client Not Supported. Server is Beta
 ; Client will not be supported when this version is Released.  Warn Client.
 S X(0)="0^     This site is a test site for Version: "_SV_"."
 S X(5)="     Client is running               Version: "_CV
 S X(7)="    "
 S X(10)="       When Version : "_SV_" is Released,  "
 S X(15)=" Client Version: "_CV_" will no longer be supported."
 S X(17)="  "
 S X(18)=" This Client Application will not work correctly."
 S X(19)=" "
 S X(20)=" Contact the Imaging System Manager to update this workstation."
 S X(30)="  "
 S X(40)="                          APPLICATION Will Continue"
 Q
NOTOK(X) ; Client Not Supported.
 S X(0)="2^   Server is running Imaging V. "_SV_"      "_$P(SVSTAT,"^",2)
 S X(1)="   "
 S X(5)=" Client is running Imaging V. "_CV
 S X(7)="  "
 S X(10)=" Version "_CV_" is no longer supported."
 S X(15)="  "
 S X(20)=" Contact the Imaging System Manager to update this workstation."
 S X(30)="   "
 S X(40)="                       APPLICATION WILL ABORT !"
 ;  Clients prior to 8, have a 'Cancel' button on Message Dialog (oversight)
 I $P(CV,".",1)=2 S X(50)="(clicking 'Cancel' will not stop the Abort.)"
 Q
OKBADTB(X) ; Client not Equal, but it is supported.
 ;  But it's T isn't the T of it's Released Patch
 S X(0)="0^   Server is running Imaging V. "_SV_"      "_$P(SVSTAT,"^",2)
 S X(3)="   "
 S X(5)="  Client is running Imaging V. "_CLVER
 S X(10)="  The Released Version of Patch "_CP_" is V. "_CV_"."_$G(OKVER(CV))
 S X(12)="  "
 S X(18)="  This Client Application will not work correctly.  You should"
 S X(20)="  update this workstation with the Released Version of Patch "_CP
 S X(21)=" "
 S X(22)="  Contact the Imaging System Manager to update this workstation."
 S X(27)="     "
 S X(30)="                          APPLICATION will Continue  "
 Q
OKBADT(X) ; Client not Equal, but it is supported.
 ;  But it's T isn't the T of it's Released Patch
 S X(0)="2^   Server is running Imaging V. "_SV_"      "_$P(SVSTAT,"^",2)
 S X(3)="   "
 S X(5)="   Client is running Imaging V. "_CLVER
 S X(10)="  The Released Version of Patch "_CP_" is V. "_CV_"."_$G(OKVER(CV))
 S X(15)=" "
 S X(18)="  Version "_CLVER_" is not supported."
 S X(19)="  "
 S X(20)="  You must update this workstation."
 S X(22)="  "
 S X(25)="  Contact the Imaging System Manager to update this workstation."
 S X(27)="     "
 S X(40)="                       APPLICATION WILL ABORT !"
 Q
OKB(X) ; Client is Not Equal to server.  Server Version / Beta
 ; Alpha/Beta Version so allow to continue. no message  
 S X(0)="1^   Alpha/Beta testing in progress for: "_SV
 Q
OK(X) ; Client is Not Equal to the server.   Warn
 S X(0)="0^   Server is running Imaging V. "_SV_"      "_$P(SVSTAT,"^",2)
 S X(5)="   Client is running   Imaging V. "_CV
 S X(7)="    "
 S X(10)="  The Client application should be updated "
 S X(15)=" "
 S X(20)="  Contact the Imaging System Manager to update this workstation."
 S X(30)="   "
 S X(40)="                       APPLICATION Will Continue"
 ;  Clients prior to 8, have a 'Cancel' button on Message Dialog (oversight)
 I $P(CV,".",1)=2 S X(50)="(clicking 'Cancel' will not stop the Client.)"
 Q
 ;
 ; Versions are the Same: If T versions are not, warn the Client.
 ; Released Client (of any version) will have the T version that the server expects, and 
 ; no warning will be displayed.
TNOTOKB(X) ; Client T is Not Equal to Server T, Beta Site.
 ;I CT,(CT'=ST) D  Q
 S X(0)="0^   Server is running Imaging V. "_SV_"."_ST_"      "_$P(SVSTAT,"^",2)
 S X(5)="   Client is running   Imaging V. "_CLVER
 S X(10)="     "
 S X(20)="  Test Versions of Patch "_SV_" other than T"_ST_" may not work correctly."
 S X(25)="     "
 S X(30)="                       APPLICATION will Continue  "
 Q
TNOTOK(X) ; Client T is Not Equal to Server T.
 ;I CT,(CT'=ST) D  Q
 S X(0)="0^   Server is running Imaging V. "_SV_"."_ST_"      "_$P(SVSTAT,"^",2)
 S X(5)="   Client is running Imaging V. "_CLVER
 S X(10)="     "
 S X(12)="  For Patch "_CP_" the released T version is:  "_ST
 S X(20)="  You must update this workstation with the Released Version."
 S X(22)="  "
 S X(25)="  Contact the Imaging System Manager to update this workstation."
 S X(27)="     "
 S X(30)="                       APPLICATION will Continue  "
 Q
BADPLC(X) ; The call to $$PLACE^MAGBAPI($G(DUZ(2))) Failed, return a message.
 ;
 I '$G(DUZ(2)) S X(0)="2^   Error: Undefined DUZ(2)"
 E  D
 . S X(0)="2^   Error: Division "_$P($G(^DIC(4,DUZ(2),0)),"^",1)_" ["_DUZ(2)_"]"
 . S X(2)="      is not an Imaging Site Parameter."
 . Q
 S X(5)="   Contact IRM.  Application will abort"
 Q