MAGGTUX2	;WIOFO/GEK Imaging utility to validate INDEX values.
	;;3.0;IMAGING;**59**;Nov 27, 2007;Build 20
	;;Per VHA Directive 2004-038, this routine should not be modified.
	;; +---------------------------------------------------------------+
	;; | Property of the US Government.                                |
	;; | No permission to copy or redistribute this software is given. |
	;; | Use of unreleased versions of this software requires the user |
	;; | to execute a written test agreement with the VistA Imaging    |
	;; | Development Office of the Department of Veterans Affairs,     |
	;; | telephone (301) 734-0100.                                     |
	;; |                                                               |
	;; | The Food and Drug Administration classifies this software as  |
	;; | a medical device.  As such, it may not be changed in any way. |
	;; | Modifications to this software may result in an adulterated   |
	;; | medical device under 21CFR820, the use of which is considered |
	;; | to be a violation of US Federal Statutes.                     |
	;; +---------------------------------------------------------------+
	;;
	Q
INIT	; If this is a continuation, initialize the variables.
	;W !,"MAGN ",MAGN
	I $P(^MAG(2005,0),"^",3)>$P(^XTMP(MAGN,0),"^",4) D
	. W !,"There are new images since this utility was last run."
	S IEN=$P($G(^XTMP(MAGN,0)),"^",3)+1 I IEN=1 D  Q  ; Already run, so start over.
	. S IEN="A"
	. W !!,"All Images were checked as of "_$$FMTE^XLFDT($P(^XTMP(MAGN,0),"^",2))
	. W !
	. W !,"For a summary of the last Check or Fix process use the menu option: "
	. W !,"     ""REV    Review a Summary of the last Fix or Check process."""
	. W !,"  or continue to Re-Check the Image file."
	W !,"Continue: where you left off, at IEN : ",IEN,"   Y/N   //N  :" R X:30
	I "Nn"[$E(X) W !,"Starting over..." S IEN="A" Q
	W !,"Continuing from IEN: ",IEN,!
	S NT=$G(^XTMP(MAGN,"AANT"))
	S NI=$G(^XTMP(MAGN,"AANI"))
	S GRINT=$G(^XTMP(MAGN,"AAGRINT"))
	S GRINI=$G(^XTMP(MAGN,"AAGRINI"))
	S GO1=$G(^XTMP(MAGN,"AAGO1"))
	S OFX=$G(^XTMP(MAGN,"AAOFX"))
	S INVG=$G(^XTMP(MAGN,"AAINVG"))
	S INVO=$G(^XTMP(MAGN,"AAINVO"))
	S NOMERG=$G(^XTMP(MAGN,"AANOMERG"))
	S OKMERG=$G(^XTMP(MAGN,"AAOKMERG"))
	S FIX=$G(^XTMP(MAGN,"AAFIX"))
	S CRCT=$G(^XTMP(MAGN,"AACRCT"))
	Q
TRK2	; Keep a Count of Short Desc, transpose to compact the list.
	S SD=$P(N2,"^",4)
	S SD=$TR(SD,"0123456789+-/\.,~`!@#$%^&*()_-={}[]|:;""'<>?","")
	S SD=$TR(SD,"abcdefghijklmnopqrstuvwxyz","ABCDEFGHIJKLMNOPQRSTUVWXYZ")
	F  Q:SD'["  "  S SD=$P(SD,"  ",1)_" "_$P(SD,"  ",2,999)
	S SD=$$TRIM^XLFSTR(SD,"LR")
	S:SD="" SD="[NO SHORT DESC]"
	S ^XTMP(MAGN,"MAIDSD",+IXT,+IXS,+IXP,"SD",SD)=$G(^XTMP(MAGN,"MAIDSD",+IXT,+IXS,+IXP,"SD",SD))+1
	Q
CHKCR(N40,IEN)	; Image has Procedure/Event CR, see if it should be CT.
	N INDXD
	D GENIEN^MAGXCVI(IEN,.INDXD)
	I $P(INDXD,"^",4)'=RADCT Q
	S CRCT=CRCT+1
	I COMMIT D
	. S FIX=FIX+1
	. S $P(^MAG(2005,IEN,40),"^",4)=RADCT
	. D ENTRY^MAGLOG("INDEX-CR",DUZ,IEN,"TUX59",MDFN,1)
	. Q
	Q
CHK45(N40,IEN)	;  Check the Origin Set of Codes.
	; N40 passed by Ref, it may be changed in here.
	N ORG,NORG
	S ORG=$P(N40,"^",6)
	I "VNFD"[ORG Q  ; Valid
	; get it's first Char.
	S $P(N40,"^",6)=$S("VNFD"[$E(ORG):$E(ORG),1:"")
	S OFX=OFX+1
	I COMMIT D
	. S FIX=FIX+1
	. S ^MAG(2005,IEN,40)=N40
	. D ENTRY^MAGLOG("INDEX-45",DUZ,IEN,"TUX59",MDFN,1)
	. Q
	Q
VALIND	;Validate the interdependency between Type, Spec, Proc/Event for Entries that have a TYpe.
	K MRY I $$VALTUX2^MAGGTUX3(.MRY,IXT,IXS,IXP) Q  ; Valid Type <-> Spec <-> Proc
	; Keep list of Generated or User entered invalid Type<->Spec<->Proc
	I $D(^MAGIXCVT(2006.96,IEN)) S ^XTMP(MAGN,"MAIDXG",+IXT,+IXS,+IXP)=$G(^XTMP(MAGN,"MAIDXG",+IXT,+IXS,+IXP))+1,INVG=INVG+1
	E  S ^XTMP(MAGN,"MAIDXO",+IXT,+IXS,+IXP)=$G(^XTMP(MAGN,"MAIDXO",+IXT,+IXS,+IXP))+1,INVO=INVO+1
	D TRK2
	Q
VALMERG(O40,N40)	; N40 Passed by Ref.
	; if the merged Proc-Spec in New 40 Node (N40) are not valid,
	; Then just take the TYPE, and revert back to old O40 Spec and Proc
	K MRY
	I $$VALTUX2^MAGGTUX3(.MRY,$P(N40,"^",3),$P(N40,"^",5),$P(N40,"^",4)) S OKMERG=OKMERG+1 Q  ; Merged values are valid
	S NOMERG=NOMERG+1
	S $P(N40,"^",4,5)=$P(O40,"^",4,5) ; Put the Spec and Proc back to original way.